247000 Series

Digital Low Resistance Ohmmeters

Item (Qty)

Cat. No.

DLRO

®

Digital Low Resistance Ohmmeters

Dual-Pak, battery-operated (10A)

247000

Single-Pak, battery-operated (10A)

247001

Single-Pak/Low-Range, battery-operated (10A)

247002

Low-Range/High-Current, line- and
battery-operated (100A)

247100 or 247101

Included Accessories

Line cord, where applicable

17032

Instruction manual

AVTM24-1J

Optional Accessories

Test leads

See chart

100 ampere current supply
for Cat. No. 247000-3 and 247001-3

247120

ORDERING INFORMATION

OPTIONAL ACCESSORIES
Input Voltage Protection

To protect the instrument when testing battery straps, this
option provides input protection against accidental
overvoltage up to 30 volts.

The option should not be specified when the instrument
will be used to test transformers and other inductive
components. This option is available on Cat. No. 247000,
247001 and 247002 only. To order, add –11 to instrument
Cat. No.

100-Ampere Adapter Plug

Cat. No. 247000 and 247001 can be ordered with an
adapter plug to allow use with the 100 ampere current
supply, Cat. No. 247120.

This capability is required by some standard methods of
testing large switchgear. ANSI C37.09, Test Procedure for
AC High Voltage Circuit Breakers, and IEC
Recommendation, Publication 56-4, High Voltage

Alternating Current Circuit Breakers Cat. No. 247101, are
two such standards. Cat. No. 247100 comes standard with
this option. This option is not available with Cat. No.
247002. To order, add –3 to instrument Cat. No.

Calibration Shunts

These four-terminal calibrating resistance standards feature
a conservative current rating to ensure against overheating.

Each shunt provides two current terminals with knurled
Allen-head cap screws and two potential terminals with
slotted screw heads. Accuracy is ±0.25%.

Item (Qty)

Cat. No.

100 A adapter plug
for Cat. No. 247000 and 247001 only

Add –3

Input voltage protection
for Cat. No. 247000, 247001 and 247002 only

Add –11

230 V (nominal), 50/60-Hz operation

Add –47

Canvas carrying case for Cat. No. 247000

35788

Instrument carrying case
for Cat. No. 247001, 247002

218748

Carrying case for leads

18313

Field test shunt, 10

Ω, current rating 0.001 A

249000*

Field test shunt, 1

Ω, current rating 0.01 A

249001*

Field test shunt, 0.1

Ω, current rating 1 A

249002*

Field test shunt, 0.01

Ω, current rating 10 A

249003

Field test shunt, 0.001

Ω, current rating 100 A

249004

Field test shunt, 0.0001

Ω, current rating 500 A

249005

Certificate of Calibration, NIST

CERT-NIST

*Furnished with protective shield