Atec Fischer_Custom_Communications_F-120-9A User Manual

F-120-9a, Bulk current injection probe

Advertising
background image





The F-120-9A has been designed to
extend the use of conducted immunity
testing over the bandwidth of 10 kHz –
230 MHz. The useable frequency range is
10 kHz - 230 MHz with an insertion loss
of less than 8 dB between 150 kHz – 200
MHz. The input power rating is 100 watts
for 30 minutes.

F-120-9A

Bulk Current Injection Probe

Fischer Custom Communications, Inc.

F-120-9A Specifications


Frequency: 10 kHz – 230 MHz
Inner Diameter:

40mm

Outer diameter: 127mm
Height: 134mm
Input Power rating: 100 watts

Accessories

FCC-BCICF-4

 Calibration Fixture

Bandwidth: 10 kHz – 230 MHz
F-52-40mm

Current Probe

Bandwidth: 10 kHz –400 MHz

20603 Earl St., Torrance, CA 90503 · Phone: 310-303-3300 Fax 310-371-6268 · email: [email protected]

 Fischer Custom Communications, Inc.

072803DS-F-120-9A

All rights reserved

 Printed in USA

Typical Data

Advertising