Model Number

Frequency

(MHz)

Network

Inductance

Maximum

Current

Voltage
Options

Power

Freq.

Number of

Lines

FCC-LISN-50-25-(X)-(XX)

.15 – 30

50uH

25A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-50-(X)-(XX)

.15 – 30

50uH

50A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-100-(X)-(XX)

.15 – 30

50uH

100A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-100-(X)-(XX)

.15 – 30

50uH

200A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-400-(X)-(XX)

.15 – 30

50uH

400A

240V / 480V

DC-60Hz 1

FCC-LISN-50-50-25-(X)-(XX)

.15 – 30

50uH

25A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-50-(X)-(XX)

.15 – 30

50uH

50A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-100-(X)-(XX)

.15 – 30

50uH

100A

240V / 480V

DC-60Hz

1, 2, 4

FCC-LISN-50-200-(X)-(XX)

.15 – 30

50uH

200A

240V / 480V

DC-60Hz

1, 2, 4

For connector options, please see table 3, (xx) defines EUT power connections, (x) defines

number of lines All the models listed above meet the performance requirements for
the 50

, 50uH LISN circuit defined in CISPR 16-1-2, 2006, including the common mode

impedance, phase and decoupling isolation.

Standard 50

LISN for CISPR-16

A wide range of EMC test specifications including CISPR 22, FCC, ANSI C63.4 and many
others use a standard 50

, 50uH and its primary variant the 50, 50uH +5 for conducted

emissions testing. CISPR 16-1-2 most precisely defines the performance requirements of
these devices.