background image

4 R&S

®

ESU EMI Test Receiver

Version 02.00, October 2007

Receiver scan

Scan

scan with max. 10 subranges with different
settings

Measurement time per frequency

selectable

10 µs to 100 s

Sweep

time sweep, span = 0 Hz

1 µs to 16000 s in steps of 5 %

Sweep time

frequency sweep, span ≥10 Hz

2.5 ms to 16000 s in steps of ≤10 %

Max. deviation of sweep time

3 %

Measurement in time domain

with marker and cursor lines
(resolution 31.25 ns)

Preselection

Preselection

can be switched off in analyzer mode

13 preselection filters

20 Hz to 150 kHz

230 kHz, fixed lowpass filter

150 kHz to 2 MHz

2.6 MHz, fixed bandpass filter

2 MHz to 8 MHz

2 MHz, tracking bandpass filter

8 MHz to 30 MHz

6 MHz, tracking bandpass filter

30 MHz to 70 MHz

15 MHz, tracking bandpass filter

70 MHz to 150 MHz

30 MHz, tracking bandpass filter

150 MHz to 300 MHz

60 MHz, tracking bandpass filter

300 MHz to 600 MHz

80 MHz, tracking bandpass filter

600 MHz to 1 GHz

100 MHz, tracking bandpass filter

1 GHz to 2 GHz

tracking highpass filter

2 GHz to 3 GHz

fixed highpass filter

3 GHz to 3.6 GHz

fixed highpass filter

Bandwidth (–6 dB), nominal

3.6 GHz to 8/26.5/40 GHz

60 MHz + f/500, YIG filter

Preamplifier switchable

between preselection and 1st mixer

Range

1 kHz to 3.6 GHz

Gain

20 dB, nominal