IEC Flicker Impedance

M6204 IEC Flicker Impedance

The M6204 unit provides the requisite lumped impedance between the AC Power

Source and the Unit Under Test (UUT) used to test for flicker compliance to IEC 61000-

3-3. Designed to meet IEC 60725 - Consideration of reference impedances and public

supply network impedances for use in determining the disturbance characteristics of

electrical equipment having a rated current ≤75 A per phase – the M6204 simulates

the typical public utility impedance characteristics found in most European countries

in order to provide a common flicker measurement reference.

IEC Flicker Impedance

Standard Features:

Three Phase Flicker Impedance Network

Supports both single and three phase

flicker testing of UUT’s up to 16Arms per

phase

Z

ref

Impedances Values per IEC 60725

Line Impedance: 0.24 Ω+ 0.15 j Ω

Neutral Impedance:

0.16 Ω + 0.10j Ω

Compatible with 360AMXT and 3120AMXT

AC Source Models

IEC Impedance is matched to AC Source

Output impedance for exact IEC 60725

matching

High Qualify Impedance Components Used

Low Thermal Drift and Forced Air Cooling

while under Load Ensures Constant Flicker

Impedance during Long Flicker Test Runs

Dual Connectors on Rear Panel

Multiple Terminal Blocks Provided for

Power, Voltage Sense and Power Analyzer

Connections Simplifies Connections

Standard 19” Rack Mount Enclosure
Fits easily on Lab Bench, on top of the AC

Power Source used or in an Instrument

Cabinet

Standards Supported:

IEC 61000-3-3 / EN 61000-3-3

IEC 61000-4-13 / EN 61000-4-13

IEC 61000-4-27/ EN 61000-4-27

IEC 60725

T H E P O W E R O F E X P E R T I S E

The Leader in AC Power Technology

FREQUENCY CONVERSION

R & D

MANUFACTURING

AEROSPACE

MILITARY

CUSTOM

A separate impedance network in the Neutral leg ensures full compliance to IEC

61000-3-3 and IEC 60725 even under imbalanced three phase load conditions. The

same three phase Impedance network is also fully capable of supporting single

phase Flicker test. In this case, the Phase A impedance and Neutral impedance

combine together to provide the required Z

ref

= 0.40 Ω + 0.25 j Ω single phase

impedance.

Three Phase and Single Phase UUT Testing

The use of high quality components with low thermal drift and high saturation

resistance ensures a stable impedance network throughout the entire flicker test

duration – typically two hours. This is augmented by efficient yet quiet forced

air cooling. Testing to the full 16 Arms per phase as required for products that

fall under the IEC 61000-3-3 Flicker Standard is fully supported by this lumped

impedance with ample margin for temporary overload conditions.

Full 16 Arms per Phase Capable

AC Source Matched

An early pioneer in the development solid-state power conversion equipment,

Pacific Power Source continues to develop, manufacture, and market both linear

and high-performance PWM AC Power Sources. Pacific’s reputation as a market

and technology leader is best demonstrated by its continuing investments in

both research and development and world-wide customer support. With corpo-

rate owned offices in the United States, Germany, the United Kingdom, and China,

local personalized support is always available.

12KVA

Three Phase

16 Arms/Phase

IEC 60725 Compliant

The M6204 impedance is factory calibrated and matched to the AMX AC Power

Source Model it is used with. This ensures that the combination of AC Source

Output Impedance and Lumped Impedance adds up to the requisite IEC 60725

Impedance values. This prevents unwanted system level errors that can occur

when the IEC Flicker Impedance is sourced from a different vendor as the AC

Power Source.