Using Type 66220-1A Transformer for the Measurement of Low Frequency EMI Currents

Application Note AN622001

Using Type 6220-1A Transformer for the Measurement of Low Frequency EMI Currents

APPLICATION

The Type 6220-1A Audio Isolation

Transformer was especially designed

for screen room use in making

conducted audio frequency

susceptibility tests as required by

MIL-STD-461/462 and other EMI

specifications.

The transformer may also be used

as a pickup device to measure low

frequency EMI currents at lower levels

than conventional current probes.

In addition, its secondary may be used

as an isolating inductor in the power

line during transient susceptibility

tests. (See Application Note

AN622001.)

DESCRIPTION

The transformer is capable of handing up

to 200 watts of audio power into its primary

over the frequency range 30 Hz to 250 KHz.

The turns ratio provides a two-to-one step

down to the special secondary winding. The

secondary will handle up to fifty amperes of

a.c. or d.c. without saturating the

transformer. Another secondary winding

is connected to a pair of binding posts

suitable for connecting to a.c. voltmeter

as directed by the applicable EMI

specifications. This winding serves to isolate

the voltmeter from power ground. Neither

the primary nor the secondary windings are

connected to the end bells of the core. The

transformer may be used as a 4-ohm

primary and 1-ohm secondary or 2.4-ohm

primary and 0.6-ohm secondary or 2-ohm

primary and 0.5-ohm secondary.

FEATURES

Provides a convenient bench model

unit with three-way binding posts on

primary and output voltmeter leads.

Standard 0.75" spacing of binding

posts allows use of standard plugs.

High current secondary uses 1/4-20

threaded studs.

Capable of handling the audio power

required by EMI specifications and

up to 50 amperes of a.c. or d.c.

through the secondary in series with

the test sample.

ADDITIONAL MODELS

Type 6220-2 100 amperes high

current transformer.

Type 6220-4 50 amperes 4 KV

transient voltage HV transformer.

Type 9707-1 10 amperes low

current transformer.

SPECIFICATIONS

Primary: Less than 5 ohms.

Secondary: One-fourth the primary

impedance.

Frequency Response: 30 Hz to

250 KHz.

Audio Power: 200 watts.

Dielectric Test: 600 volts d.c.

primary to secondaries and each

winding to end bells.

Secondary Saturation: 50

amperes a.c. or d.c. maximum.

Turns Ratio: Two-to-one step down.

Secondary Inductance:

Approximately 1.0 mH (unloaded).

Weight: 18 pounds.

Size: 4.5" wide, 5.25 " high, 6.25"