Specification

Lightning Surge Simulator

LSS-6230

Parameter

■ Common

Polarity

Interval

No. of output setting

■ Surge generating unit

1.2/50μs-8/20μs

Combination waveforms

0.5μs-100kHz

Ring wave

Coupling network

Decoupling coil

AC EUT power capacity

DC Eat power capacity

Phase angle control

■ Surge generating unit for external CDN

10/700μs-5/320μs

Combination waveforms

■ Other

Voltage monitor

Current monitor

External communication

Power supply

Dimension

Mass

Specification

Positive / Negative

(Minimum charging time) ∼999 sec. 1 sec. step

1∼999 times 1 time step

Voltage surge

Current surge

Minimum charge time

Output impedance

Voltage surge

Current surge

Minimum charge time

Output impedance

Line - Line : 18μF, Line - PE : 10Ω+9μF, Line - PE simultaneous coupling (L+N-PE) : 9μF/9μF

1.5mH

Single phase AC 240V 16A MAX (50/60Hz)

DC125V/16A MAX

0∼360°

±10°

, Based on set injection / return angle

Voltage surge

Current surge

Minimum charge time

Output impedance

BNC output, 1/1000±10%

BNC output, 1mV/A±10%

RS-232C optical communication

AC100V ∼120V±10%, AC200V ∼240V±10%,50/60Hz Power consumption : Less than 300VA

W430×H515×D500 mm(Projection excluded)

Approx. 65kg

Output voltage

Front time

Duration

Output current

Front time

Duration

Output voltage

Rise time

Frequency

2nd peak voltage

3rd peak voltage

4th peak voltage

Output voltage

Front time

Duration

Output current

Front time

Duration

0.5∼6.0kV ±10%

1.2μs±30%

50μs±20%

250∼3000A ±10%

8μs±20%

20μs±20%

10 Sec.

2Ω±10%

0.5∼6.0kV ±10%

0.5μs±0.15μs

100kHz±20kHz

40-110% of 1st peak voltage

40-80% of 2nd peak voltage

40-80% of 3rd peak voltage

5 Sec.

12 Ω±3 6 Ω at 12 Ω selection in interruptive resistance

30 Ω±8 Ω at 30 Ω selection in interruptive resistance

0.5∼6.0kV ±10%

10μs±30%

700μs±20%

12.5∼150A ±10%

5μs±20%

320μs±20%

15 Sec.

40Ω±10%

w w w . n o i s e k e n . c o m

Lightning Surge Simulator
Conforming to IEC61000-4-5 ed2 Standard
Ring wave conforming to ANSI/IEEE C62.45 available
Max. voltage 6.6kV output focusing on the practical use
Monitor terminal standard equipped so as for easy waveform pre-checking
Interlock built-in as the emergency stop function for safety
Remote control software from PC ready as the option besides the stand-alone operation
AC/DC CDN standard equipped. Available up to 3-phase AC500V 50A as the option