. Non-directional (isotropic) measurement with

three-channel measurement probe

. High dynamic range due to three-channel digital results

processing

. Optical interface for calibration and result data transfer

. Excellent measurement accuracy with automatic zeroing

even during field exposure

. Easy to use

. Shock, dust and water-resistant

. Built-in stand and tripod bush

. Calibrated

Applications

Precision measurement of electric field strength for personal

safety at work where high radiation levels are present, and for

applications involving electromagnetic compatibility (EMC),

such as:

± Service work on transmitting equipment

± Working with plastic welding machines

± Operating diathermy equipment and other medical instruments

producing short-wave radiation

± Drying equipment in the tanning and timber industries

± Field strength measurements in TEM cells and absorber

chambers

Features

The EMR-20 and EMR-30 Radiation Meters are compact, battery-

powered, and easy to operate. The remote sensor is a non-

directional measurement probe. The built-in optical interface

allows each of the three axes to be evaluated separately and also

allows complete remote-control of all instrument functions.

Long operating time from batteries

The EMR-20/30 is equipped with rechargeable batteries as

standard. These can be recharged while still fitted in the instru-

ment, and give about 8 hours operating time. If dry batteries are

used, up to 30 hours operating time can be expected.

Calibration

Every instrument in the EMR range is calibrated for absolute level

and linearity vs. level. Typical frequency response values are also

provided (CAL factor) together with a calibration certificate. The

frequency response of every C-series instrument (EMR-20C/30C)

is measured individually, and a calibration report containing all the

measured values is included with the instrument. The instruments

can be calibrated automatically via the bi-directional optical inter-

face. This allows easy calibration by the user or by recognized

national calibration laboratories, resulting in a significant reduction

Radiation Meters

EMR-20, EMR-30

EMR-20,

EMR-30

100 kHz to 3 GHz

For isotropic measurements

of electric fields

Wandel &Goltermann GmbH &Co.

Elektronische Meûtechnik

Postfach 12 62

72795 Eningen, Germany

Tel. +49 (0) 7121-86 16 16

Fax +49 (0) 7121-86 14 80

e-mail: [email protected]

http://www.safety-test-solutions.de