Led total flux measurement system, Measurements in the led manufacturing process, General reference information – Atec Konica-Minolta-CL-200A User Manual

Page 5

Advertising
background image

When made from blue LED and phosphor

The blue light emitted by the LED mixes with the yellow light

emitted by the phosphor to create white light.

Problem:

Since the spectral emission distribution of the
blue light emitted by the LED varies for each unit,
variations in the resulting white light will occur. Since
usually LED lamps use several LEDs, control of
color mixing is necessary.

General solution:

Measure the spectral emission

characteristics of each LED element
and rank them accordingly.

Measure the emission characteristics of the

phosphor and rank accordingly.

 Combine the ranked LED elements and ranked

phosphor materials to achieve the desired white

light.

 Inspect the output light quality of the final assembled white LED lamp.

How the CL-200A can help:
The CL-200A can measure the chromaticity from the phosphor and also
inspect the output light quality of the final assembled white LED lamp.

LED total flux measurement system

This system combines our top-of-the-line Spectroradiometer CS-2000 modified for illuminance measurement with an LED
total flux measurement adapter to create an LED measurement system that utilizes a spectral measuring instrument
conforming to CIE 122-1996 as the receptor. The total flux emitted in all directions by the LED is diffused by the integrating
sphere and received for measurement by the spectroradiometer.

This system conforms to CIE 127:2007.

Since the spectral response of the receptor matches the CIE spectral luminous efficiency function V(

λ

), there is no need to

perform troublesome color correction.

To enable accurate measurements, a self-absorption compensation function is provided to compensate for the reduction
in integrating sphere output due to self absorption of the light source when it is lit inside the integrating sphere.

General Reference Information

Measurements in the LED manufacturing process

LED Total Flux Measurement System

PC

Baffle

LED

LED holder

Integrating

sphere unit

Self-absorption

compensation LED

Constant-current

power supply

Spectroradiometer CS-2000

(modified for luminance measurement)

LED measurement

software

Cross-section A

Illuminance (lx)

Horizontal distance (m)

H

ei

gh

t (

m

)

0

0

1

1

2

2

3

3

4

-1

-2

-3

300

100

50

10

30

5

Colors mix to create white light!

Blue light emitted by LED element

Yellow light emitted by phosphor

Package

Electrode

Wavelength (nm)

LED element

Phosphor

Wavelength (nm)

Variations in white light

Advertising