National and international regulations on
electromagnetic compatibility require that
electrical and electronic equipment is
designed to be resistant to induced RF
signals in power lines and data lines.
As radio traffic and RF interference levels
continue to increase all over the world,
the issue becomes one of growing
importance.
Previously, the task of testing equipment
for susceptibility to induced RF was
lengthy and prone to error. The NSG
2070 changes all that. It is one of the first
instruments on the market to offer a
simple, self-contained, self-calibrating
system for fast, effective, reliable testing
for susceptibility to induced RF in power
lines and data lines for both compliance
testing and pre-compliance
characterisation. The system fulfills all
the requirements of IEC 61000-4-6.
The NSG 2070-1 generator unit
incorporates a 100kHz - 250MHz HF-
synthesizer and a high power amplifier.
NSG 2070 is compatible with all types of
power line and data line coupling options;
namely coupling/decoupling networks,
electromagnetic clamp and current
injection probe.
Test parameters are pre-programmed so
that standard procedures can be simply
invoked. The ability to create fully
customized tests with user-specified
parameters is also provided for more
detailed characterisation work.

Self-calibration
Calibration of the test rig as required by
IEC 61000-4-6 to ensure a constant
frequency output is simple with NSG 2070.
The instrument automatically and quickly
calibrates itself to the chosen coupling
method and stores the calibration table
for future reference.

Safety
Power-down is automatic in the event
of violation of any safety condition and
there is a stop button that can be used
to invoke an immediate power-down.
When operated under software control,
hitting any of the keys on the keyboard
during the test has the same effect. The
synthesizer and amplifier are processor-
controlled to guarantee safe, error-free
test procedures. The load-independent
output stage is short-circuit and open-
circuit protected.

Controllability
Manual control of the NSG 2070 is via five
function keys and a series of LCD menus
which allow the engineer to calibrate the
test set-up, and program test procedures
simply by selecting built-in IEC 61000-4-6
test parameters, or by setting custom
levels. The RUN, PAUSE and STOP
buttons are used to control tests.

Software Control
The Windows-based software control
module WIN 2070 provides real-time
remote control of all the NSG 2070
functions, along with a whole suite of
additional test sequencing, editing, saving
and reporting tools. Using intuitive
Windows screens and a virtual instrument
front panel, engineers can set-up and run
single tests - just as under manual control
- or can sequence a whole series of tests
for automatic execution.
WIN 2070 includes a professional report
generator which can be used to produce
hard copy test reports automatically for
management, engineering or quality
records, or as compliance documents
to meet legal requirements.

IEC 61000-4-6 Test System

Self contained package

Can perform all standard test techniques

NSG 2070

Options

WIN 2070

WINDOWS™ software

CDN 721

Current injection probe (CIP)

INA 721

Calibration set for CDN 721

KEMZ 801

EM clamp, including cable

INA 725

Calibration set for CDN 725

CDN M3 / 32A

Coupling network

CDN M5 / 32A

Coupling network

CDN S4

Coupling network

CDN T4

Coupling network

MD 720

Monitor probe complete