Atec Solar-9719-1N User Manual

Solar electronics company

Advertising
background image

SOLAR ELECTRONICS COMPANY

A Division ofA. T. Parker lne.

11158 CHANDLER BLVD.

N. HOLLYWOOD, CALIFORNIA 91601

Telephone' (818) 755-1700

Fax: (818) 755-0078

E-Mail (

[email protected]

)

PAGES:

2

DATE:

9/25/03

COMPANY:

Advanced Test Equipment

COMPANY FAX:

1(858)558-6570

ATTENTION:

Jim Tighe

FROM:

Scott McDonald

REF:

9719-IN

calibration in 300 ohm loop

COMMENT:

The network analyzer was set up to be a 150 ohm system by placing a 100 ohm resistor in series

with the 50 ohm generator and a 100 ohm resistor in series with the 50 ohm receiver (300 ohm

loop) and normalized. Next, the current probe, in a calibration fixture, was inserted. The signal

generator was then connected to the connector on the injection probe. A 150 ohm resistor was

placed in. shunt with one end of the fixture and a 100 ohm resistor was placed in series with the

receiver and connected to the other end of the calibration fixture completing the 300 ohm loop.

I hope this help,

Scott McDonald

Please visit our Web page

(