Accessories, Related products, Precision power analyzer wt3000 – Atec Yokogawa-WT3000 User Manual

Page 10: Measurement using clamp-on probe

Advertising
background image

10

Precision Power Analyzer WT3000

Due to the nature of this product, it is possible to touch its
metal parts. Therefore, there is a risk of electric shock, so
the product must be used with caution.

Two leads in a set. Use 758917
in combination with 758922 or
758929.
Total length: 75 cm
Rating: 1000 V, 32 A

758917

Measurement leads

For connection to measurement
leads (758917). Two in a set.
Rating: 300 V

758922

Small alligator adapters

For connection to measurement
leads (758917). Two in a set.
Rating: 1000 V

758929

Large alligator adapters

(spring-hold type) Two adapters
in a set.

758923

*1

Safety terminal adapter set

Screw-fastened adapters. Two
adapters in a set. 1.5 mm Allen
wrench included for tightening.

758931

*1

Safety terminal adapter set

Two adapters (red and black) to
a set. Used when attaching
banana plug to binding post.

758921

Fork terminal adapter

For conversion between male
BNC and female banana plug

758924

Conversion adapter

(BNC-BNC 1m/2m)
For connection to simultaneously
measurement with 2 units, or for
input external trigger signal.

366924/25

*2

BNC cable

2 pieces (red and black) in one
set. Rating 1000V

701959

Safety mini-clip set (hook Type)

For connection the external input
of the WT3000 to current sensor.
Length:50cm

B9284LK

*3

External Sensor Cable

• Wide dynamic range:

-600 A to 0 A to +600 A (DC)/600 A peak (AC)

• Wide measurement frequency range:

DC to 100 kHz (-3 dB)

• High-precision fundamental accuracy:

±

(0.05% of rdg + 40

µ

A)

• Superior noise withstanding ability and CMRR

characteristic due to optimized casing design

*751521/751523 do not conform to CE Marking

For detailed information, see Power Meter Accessory Catalog Bulletin
7515-52E.

751521,751523

Current Sensor Unit
DC to 100 kHz/600 Apk

• DC~800 kHz/60 Apk, DC~500 kHz/200 Apk,

DC~300 kHz/1000 Apk

• Wide dynamic range:

±

0-1000 A(DC) /1000 A peak (AC)

• Wide measurement frequency range:

DC and up to 800 kHz

• High-precision fundamental accuracy:

±

(0.05% of reading + 30

µ

A)

±

15 V DC power supply, connector, and load resistor required.

For detailed information, see Current Sensors & Accessories Catalog
Bulletin CT1000-00E.

CT60/CT200/CT1000

Current Sensors

• Measurement frequency range:

30 Hz to 5 kHz

• Basic accuracy:

±

0.3% of reading

• Maximum allowed input:

AC 1000 Arms, max 1400 Apk (AC)

• Current output type: 1 mA/A

A separately sold fork terminal adapter set (758921), measurement
leads (758917), etc. are required for connection to WT3000. For detailed
information, see Power Meter Accessory Catalog Bulletin 7515-52E.

751552

Current Clamp on Probe
AC 1000 Arms (1400 Apeak)

Current

Output

Current

Output

Current

Output

758917

758921

*751521/751523 and CT series do not conform to CE Marking.

ACCESSORIES

Related products

*1 Maximum diameters of cables that can be connected to

the adapters
758923 core diameter: 2.5 mm or less;
sheath diameter: 4.8 mm or less
758931 core diameter: 1.8 mm or less;
sheath diameter: 3.9 mm or less

*2 Use with a low-voltage circuit (42V or less)
*3 The coax cable is simply cut on the current sensor side.

Preparation by the user is required.

Current Sensor Unit Current Transducer Clamp on Probe

Adapters and Cables

Typical Voltage/Current Connections

Measurement using current sensor

Current measurement using direct input terminal

Measurement using voltage input terminal

Power meter’s
voltage
input terminal

Power meter’s
current
input terminals

Connector

(B8200JQ)

Four load resistors*

(B8200JR)

connected inparallel

DC power supply
(

±15 V, 1 A)

CT1000

Unit whose current
is to be measured

Unit whose current
is to be measured

Power meter’s voltage
input terminal

* A burden resistor is required for the CT1000, CT200, CT60, and 751574.

Measurement using clamp-on probe

Power meter’s current
direct input terminal

Current output type

Connection example

758921

701959

758917

758923

758931

758922

758929

758921

758923

758931

758917

751552

758921

Unit whose voltage
is to be measured

Unit whose voltage
is to be measured

Advertising