Temperature Range:

1,3

-80° to +225°C (60 Hz System)
-75° to +225°C (50 Hz System)

Typical Temperature Transition Rate (air)

1,2

-55° to +125°C: approximately 10 seconds or less

2

+125° to -55°C: approximately 10 seconds or less

2

System air flow output

2.4 to 9 liters/second (5 to 18 scfm) CONTINUOUS

Temperature accuracy

1.0°C (when calibrated against NIST transfer standard)

Temperature set, display and resolution

± 0.1°C

Temperature Control:

DUT Sensor Ports

Type T and Type K Thermocouple ports standard

DUT Control

Control to within ± 0.1°C; SELF-TUNING available in DUT Control

Remote interface ports

IEEE-488, RS232C Serial, and Start Test/End of Test/Stop
on First Fail (ST/ET/SFF)

1

Note: Ultimate low temperature and system performance may vary under operating conditions less than or greater than nominal.

2

Note: Transition performed under nominal operating conditions.

3

Note: Low temperature extremes can be achieved at reduced airflow rates.

Model

TP04

3

1

0A

ThermoStr

eam

®

S

yst

em Specifica

tions

4

Note: US Patent no. 4,734,872

TP04310A

TEMPERATURE PERFORMANCE AND AIRFLOW CAPACITY

USER FEATURES

Modes of Operation

Two: Manual and Program Modes

Test set-up configurations

12 Manual Mode test programs and 12 Program Mode
test programs may be created

Test set-up storage

11 Manual Mode test programs, 11 Program Mode
test programs and 11 affiliated “Define Parameters”
test set-ups can be stored for later recall.

Ramp/soak/cycle configurations

In Program Mode, up to 12 sequences per test set-up;
table is displayed on-screen

DUT temperature control

Patented

4

Dual Loop Temperature Control

Status indicators

Real-time status displayed on-screen and via remote
interface

Purge flow tester interface

Dry air purge protects tester electronics

protection

from condensation

Purge flow capacity

0.25 to 1.5 liters per second (0.5 to 3 scfm) airflow

Calibration

Automated, simplified and accurate for all airflows
and DUT types

Thermal head raising and lowering

Pneumatic control on thermal head,
operated manually or via remote interface

Head positioner movement

Manual locking (4 locks), 360° head rotation; head
can be manually pivoted, turned, tilted and vertically
swung for ease of interface at tester site.

Manipulator (arm) movement

Motorized raising and lowering of arm;
330° positioning range around the base unit

Part No. SL10290 R/C

Mobile Temperature System for testing components, hybrids, parts, modules,
subassemblies and printed circuit boards at precise temperature