Atec Vaisala-HMI41SETB5B User Manual

High performance sensor

Advertising
background image

www.vaisala.com

HMI41 Indicator and HMP42/HMP46 Probes

The Vaisala HUMICAP

®

Humidity

Indicator HMI41 fitted with the Vaisala
HUMICAP

®

Humidity and Temperature

Probes HMP42 or HMP46 can be used
for spot checking and field calibration
applications.
In addition to displaying the humidity
and temperature readings, the HMI41
indicator calculates dew point and wet
bulb temperature, absolute humidity
and mixing ratio.
The indicator has an easy-to-read two
line liquid crystal display. The display
units (metric or non-metric) are easily
selected.
These features, plus fast response
time, high measurement accuracy and
excellent stability, as well as the unique
properties of the probe chosen – either
the HMP42 or the HMP46 – make
the HMI41 indicator and HMP42/46
combination an ideal choice for the
most demanding applications.

Vaisala HUMICAP®

Humidity and Temperature

Probe HMP42

The HMP42 probe can be used for spot
checking humidity and temperature
in applications which require an
extremely thin probe. Typically the
probe is used for monitoring the drying
of structures during construction or
after water damage. It is ideal to be
used when measuring in any tight
places, in ducts or chambers or, for
example, under a linoleum floor.
The probe diameter is only 4 mm,
allowing access into very small, tight,
and hard-to-reach spaces.

Vaisala HUMICAP®

Humidity and Temperature

Probe HMP46

Typical applications for the HMP46
are plant maintenance, installation
and inspection of air conditioning
systems, production and storage areas
and production processes. The HMP46
operates in full humidity range of
0 ... 100 %RH. The temperature range
is from -40 to +100 °C (-40 ... +212 °F).
For short periods of time, the probe
can withstand temperatures up to
+180 °C (+356 °F).
The HMP46 probe is solid and
rugged. Its stainless steel probe is
made to withstand rough handling in
mechanically demanding applications.
The probe’s long shaft can also reach
otherwise unreachable places.

High Performance Sensor

The HMP42/46 probes incorporate
Vaisala HUMICAP

®

Sensor. This sensor

has high accuracy, excellent long-term
stability and negligible hysteresis.
In addition, the sensor is insensitive
to dust, particulate dirt and most
chemicals.

Features/Benefits

RH measurement range

0 ... 100 %RH

Temperature measurement

range -40 ... +100 °C

(-40 ... +212 °F), with the

HMP46 only for short periods

up to +180 °C (+356 °F)

Calculates dew point, wet bulb

temperature, absolute humidity

and mixing ratio

Versatile and easy-to-use

Incorporates Vaisala HUMICAP®

Sensor

Excellent stability

Data collection with serial line

NIST traceable (certificate

included)

Optional carrying case and

calibration cable

The Vaisala HUMICAP

®

Humidity

Indicator HMI41 equipped with the

Vaisala HUMICAP

®

Humidity and

Temperature Probe HMP46 – a rugged

stainless steel probe for mechanically

demanding and high temperature

applications.

The Vaisala HUMICAP

®

Humidity

Indicator HMI41 equipped with the

Vaisala HUMICAP

®

Humidity and

Temperature Probe HMP42 – an

extremely thin probe allowing access

into very small, tight, hard-to-reach

spaces.

Advertising