Mixed Signal Oscilloscopes — MSO3000 Series, DPO3000 Series

Acquisition Modes

Mode

Description

Sample

Acquire sampled values.

Peak Detect

Captures glitches as narrow as 2 ns at all sweep

speeds.

Averaging

From 2 to 512 waveforms included in average.

Envelope

Min-max envelope reflecting Peak Detect data over

multiple acquisitions.

Hi Res

Real-time boxcar averaging reduces random noise

and increases vertical resolution.

Roll

Scrolls waveforms right to left across the screen at

sweep speeds slower than or equal to 40 ms/div.

Waveform Measurements

Measurement

Description

Cursors

Waveform and Screen.

Automatic

Measurements

29, of which up to four can be displayed on screen

at any one time. Measurements include: Period,

Frequency, Delay, Rise Time, Fall Time, Positive

Duty Cycle, Negative Duty Cycle, Positive Pulse

Width, Negative Pulse Width, Burst Width, Phase,

Positive Overshoot, Negative Overshoot, Peak

to Peak, Amplitude, High, Low, Max, Min, Mean,

Cycle Mean, RMS, Cycle RMS, Positive Pulse

Count, Negative Pulse Count, Rising Edge Count,

Falling Edge Count, Area and Cycle Area.

Measurement

Statistics

Mean, Min, Max, Standard Deviation.

Reference Levels

User-definable reference levels for automatic

measurements can be specified in either percent

or units.

Gating

Isolate the specific occurrence within an acquisition

to take measurements on, using either the screen,

or waveform cursors.

Power Measurements (Optional)

Measurement

Description

Power Quality

Measurements

V

RMS

, V

Crest Factor

, Frequency, I

RMS

, I

Crest Factor

, True

Power, Apparent Power, Reactive Power, Power

Factor, Phase Angle.
Power Loss: T

on

, T

off

, Conduction, Total.

Switching Loss

Measurements

Energy Loss: T

on

, T

off

, Conduction, Total.

THD-F, THD-R, RMS measurements.
Graphical and table displays of harmonics.

Harmonics

Test to IEC61000-3-2 Class A and MIL-STD-1399.

Ripple

Measurements

V

ripple

and I

ripple

.

Modulation Analysis

Graphical display of +Pulse Width, -Pulse Width,

Period, Frequency, +Duty Cycle, and -Duty Cycle

modulation types.

Safe Operating Area

Graphical display and mask testing of switching

device safe operating area measurements.

dV/dt and dI/dt

Measurements

Cursor measurements of slew rate.

Waveform Math

Characteristic

Description

Arithmetic

Add, subtract, multiply, and divide waveforms.

Math Functions

Integrate, Differentiate, FFT.

FFT

Spectral magnitude. Set FFT Vertical Scale

to Linear RMS or dBV RMS, and FFT Window

to Rectangular, Hamming, Hanning, or

Blackman-Harris.

Advanced Math

Define extensive algebraic expressions including

waveforms, reference waveforms, math functions

(FFT, Intg, Diff, Log, Exp, Sqrt, Sine, Cosine,

Tangent), scalars, up to two user-adjustable

variables and results of parametric measurements

(Period, Freq, Delay, Rise, Fall, PosWidth,

NegWidth, BurstWidth, Phase, PosDutyCycle,

NegDutyCycle, PosOverShoot, NegOverShoot,

PeakPeak, Amplitude, RMS, CycleRMS, High,

Low, Max, Min, Mean, CycleMean, Area,

CycleArea, and trend plots), e.g.,(Intg(Ch1 -

Mean(Ch1)) Ч 1.414 Ч VAR1).

Software

Product

Description

NI LabVIEW

SignalExpress™

Tektronix Edition

A fully interactive measurement software

environment optimized for the MSO/DPO3000

Series, enables you to instantly acquire,

generate, analyze, compare, import, and save

measurement data and signals using an intuitive

drag-and-drop user interface that does not require

any programming.

Standard MSO/DPO3000 Series support for

acquiring, controlling, viewing, and exporting

your live signal data is permanently available

through the software. The full version (SIGEXPTE)

adds additional signal processing, advanced

analysis, mixed signal, sweeping, limit testing, and

user-defined step capabilities and is available for a

30-day trial period standard with each instrument.

OpenChoice

®

Desktop

Enables fast and easy communication between

a Windows PC and the MSO/DPO3000

Series. Transfer and save settings, waveforms,

measurements, and screen images. Included

Word and Excel toolbars automate the transfer

of acquisition data and screen images from

the oscilloscope into Word and Excel for quick

reporting or further analysis.

IVI Driver

Provides a standard instrument programming

interface for common applications such as

LabVIEW, LabWindows/CVI, Microsoft .NET, and

MATLAB.

eScope

Enables control of the MSO/DPO3000 Series over

a network connection through a standard web

browser. Simply enter the IP address or network

name of the oscilloscope and a web page will be

served to the browser.