Automated video measurement set – Atec Tektronix-VM5000 User Manual

Page 11

Advertising
background image

Video Measurement • www.tektronix.com/video

11

Automated Video Measurement Set

VM5000

Hardware Accessory
Specifications

Option VGA Video Measurements

*2

(Continued)

Characteristic

Accuracy

Description

Timing

V Timing (lines) – Front and Back Porch,

Read out (precision) is 1 line. Functions within

Top and Bottom Border, Addressable Lines

±10 lines of VESA reference value

Frequency

H and V sync, Pixel Clock Frequency

±0.01% of reading

Transient Response

Video Rise and Fall Time

±5% of reading

VESA 6.8

Measurement Range >1.3 ns

Video Transient Response: Utilizes Course grille, VESA

Section 6.2, 6.3, 6.8 Displayed results corrected for

RGB measurement system bandwidth limitations

Video Rise and Fall Time Measurement Range

±10% of reading

800 ps to 1.3 ns

Video Rise and Fall Time Measurement Range

±20% of reading

450 ps to 800 ps

RGB System Rise Time

350 ps (typical)

Sync Rise and Fall Time Measurement Range

>5 ns

±5% VESA Section 7.1-7.4

Sync Rise and Fall Time Measurement Range

±11%

Displayed results corrected for H/V measurement

2 ns to 5 ns

system bandwidth limitations

RGB and HV Sync Overshoot and Undershoot

±2% of reading (typical)

Amplitude %, Settle Time: 0 to 1 ns

RGB and HV Sync Overshoot and Undershoot

±1% of reading (typical)

Amplitude %, Settle Time: 1 to 10 ns

RGB and HV Sync Overshoot and Undershoot

±T rise (typical)

VESA 6.3

Settling Time, Amplitude >5%

Jitter

H Sync Jitter (ns)

100 ps ± 15 ppm x H-Sync period ± 14% of reading

VESA 7.5 Requires VESA compliant amplitude,

noise, rise and fall characteristics

H Sync Jitter (% of Pixel Clock Period)

<4%

Measurement Range: <200 MHz PCF

H Sync Jitter (% of Pixel Clock Period)

<7.5%

Measurement Range: 200 to 400 MHz PCF

*

2

Specifications apply with use of Measurement Interface Unit (MIU).

Advertising