Atec Yokogawa-TA320 User Manual

Time interval analyzer & universal counters, Ta320, Specifications

Advertising
background image

13

TIME INTER

V

AL ANAL

YZER & UNIVERSAL COUNTERS

RECORDERS

WAVEFORM

MEASURING

INSTRUMENTS

DIGITAL

MEASURING

INSTRUMENTS

INDEX

TIME INTERVAL ANALYZER & UNIVERSAL COUNTERS

TA320

Specifications Related to Measurement

SPECIFICATIONS

Specifications Related to Inputs/Outputs

Note: All inputs are diode-protected and terminal grounds are connected to the

enclosure’s ground.

*

1

: Typical value.

*

2

: The value when the warm-up time has expired under the reference operating

conditon with the coupling and input impedance set at DC and 1 M

, respectively.

*

3

: The value when the output is received into 50

at a 1 M

input impedance.

Item

Impedance*

1

Coupling
Trigger level
Maximum voltage range
Minimum input pulse width
Setup time

External Arming Input (the terminal is shared by external gating inputs)

Specifications

10 k

DC
TTL
–8 to +13 V (DC+ ACpeak)
30 ns
70 ns (In order for arming input to be valid, it must
precede the measured signal by no less than 70 ns.)

Specifications

50

/1 M

(input capacitance: 20 pF)

100 MHz

DC/AC (input impedance: 1 M

: cutoff frequency 35 Hz;

: 50

: cutoff frequency 680 kHz)

–5 to + 5 V
50

: 5 Vrms

1 M

: 40 V (DC + ACpeak)

(DC

input frequency

100 kHz)

3.5/f (MHz) + 5 V (DC + ACpeak)
(100 kHz < input frequency

100 MHz)

400

µ

Vrms

100 mVp-p

10 ns

Voltage rangesetting
Accuracy *

2

Resolution
Input signal condition
Method
Setpoint time*

1

Item

Input impedance*

1

Frequency characteristics
(-3 dB)*

1

Input coupling

Operating voltage range
Maximum input voltage

Amplifier noise*

1

Sensitivity
Minimum input pulse
width
Trigger level

Auto trigger

Inputs to A and B Channels

+5 to –5 V

±

(10 mV + 4% of setpoint)

5 mV
1 kHz to 50 MHz
Singe/Repeat
0.7 s

Item

Input impedance*

1

Input coupling
Trigger level
Maximum input voltage
range
Minimum input pulse width
Setup time

External Inhibit Input

Specifications

10 k

DC
TTL

–8 to +13 V (DC + ACpeak)

30 ns
70 ns (In order for inhibit input to be valid, it must
precede the measured signal by no less than 70 ns.)

Item

Outputs impedance*

1

Outputs signal level*

3

Monitor Outputs A and B

Specifications

50

Approximately 1/4 of the input signal (within

±

5 V)

Item

Frequency range
Impedance
Coupling
Voltage level
Maximum voltage range

Reference Input

Specifications

10 MHz

±

10 Hz

1 k

min.

AC
1 Vp-p min.
–10 to + 10 V

Item

Frequency*

1

Impedance*

1

Coupling
Voltage level*

1

Reference Output

Specifications

10 MHz
50

min.

AC
1 Vp-p min.

Item

Time stamp mode

Hardware histogram mode

Sampling Modes

Specifications

Acquires measurements along with “time stamp” data, which represent the time that the respective measurements occurred, to record a set of these
data as time-series data.
Records measurements as the frequency data for a histogram.

Item

Maximum sampling rate

Sampling period

Maximum sample size

Sampling

Time stamp mode

MIN (71ns)
1, 2, 4, 10, 20, 40, 100, 200, 400

µ

s, 1, 2, 4 ms.

The total sampling time is 320 seconds, including the time for arming.
Duty ratio and phase difference measurements: 16,000 samples
Other emasurements:

32,000 samples

Hardware histogram mode

The total sampling time is 320 seconds.

99,999,999 samples, (10

8

-1)

excluding duty ratio and phase difference measurements

Specifications

Continuous 14 M samples/s (71-ns intervals);

7 M samples/s (142-ns intervals) in the case of phase difference and duty ratio measurements

Item

Refresh rate*

1,

*

2

Measurement Refresh Rate (hardware histogram mode only)

Specifications

400 ms