The Relay Switch is a device that connects to a Room Alert 32W, 32E and/

or 4E unit and provides four (4) relay outputs that can turn on/off (i.e. open

or close) when an alarm is detected. It includes three (3) relays that can each

be individually controlled via the Room Alert web interface or automatically

in response to an alarm condition. The fourth relay is used as a general alarm

output and will be turned on or activated whenever any of the first three relays

are activated.

To configure Room Alert to use the Relay, access the ‘Alarm Options’ tab of the Settings screen and be

sure to select ‘Relay’ from the ‘Connected Signal Tower / Relay’ configuration box. Next, connect the

Relay box to the black output connector on the Room Alert unit using the cable provided. The sensor

wire included with the relay can be used to connect each of the relay outputs to the desired external

device. A common application is to connect one of the relay outputs to an input on a building alarm or

security panel.

When the Relay is connected, a light on the bottom left corner of the Relay box will indicate that is has

power. Each of the relay outputs can be tested by simply clicking the associated relay graphic on the web

interface for the Room Alert monitor you are using. Relay outputs should be tested on a regular basis to be

sure they are functioning as expected in the event of an alarm condition.

Each Relay can also optionally be turned on/off automatically in the event that an alarm is triggered or

when an alarm clears. These options are available on the ‘Alarm Options’ tab of the Settings screen on

the Room Alert. Device ManageR can also communicate with any Room Alert 32W, 32E and/or 4E on

the network and automatically toggle the relay outputs based on current alarm conditions.

Sensor cable used to connect the relay outputs to other devices can be any low voltage cable such as bell

wire, speaker cable, data cable or telephone cable. Minimum voltage insulation 50V, minimum current

carrying capacity of at least 1A. Sensor cable must exceed the minimum electrical requirements of the

device being connected. Maximum recommended length is approximately 100’ although shorter lengths

will yield more reliable performance. Distances up to 900’ are possible although the specific setup

should be tested to ensure proper operation.

Relay Switch

(Low Voltage Devices)

Instructions For Installing The Relay Switch

Application Note

Room Alert

AVTECH Software

Phone 401.628.1600

Sales 888.220.6700

Web AVTECH.com

© 1988 - 2012 AVTECH Software, Inc. All Rights Reserved.

The Screw Connectors On The Sensor ID Boxes Are Volt-Free Contacts Only. Do Not Connect These Terminals To Any Live Circuit.

A Qualified Electrician Should Be Consulted To Test Any Wires You Connect To The Room Alert ID Box For The Presence Of Electrical

Voltages And If Any Are Detected, They Must Not Be Wired To The ID Box. The ID Box May Become Dangerous If You Connect It

To A Live Circuit. Never Connect Main Power To Any Of The Room Alert Sensors Unless Specifically Instructed To Do So Using The

AVTECH Software 5V Power Adapter. If Required, An AVTECH Software 5V Power Adapter Will Be Included With That Sensor.

DO NOT Use Switch Sensors In ‘Explosive’ Environments Unless Approved For Those Environments.

IMPORTANT SAFETY NOTICE

Advertising