B&K Precision 2707B - Datasheet User Manual

Manual ranging true rms tool kit, Rue rms, Model 2707b data sheet

Advertising
background image

10 A range: ±(3.5 % rdg + 3 dgts)

Input Protection

0.5 A/500 V & 10 A/600 V fast blow ceramic fuses

10A Input

10 A for 60 sec max. followed by a 10 minute cooling period

AC Cu rrent (50 Hz -500 Hz )

True RMS

Applies

Ranges

20 mA, 200 mA, 10 A

Resolution

10 uA, 100 uA, 10 mA

Accuracy

20 mA to 200 mA ranges: ±(2.0 % rdg + 8 dgts)
10 A range: ±(3.5 % rdg + 8 dgts)

Input Protection

0.5 A/500 V & 10 A/600 V fast blow ceramic fuses

Crest Factor

<3

10A Input

10 A for 60 sec max. followed by a 10 minute cooling period

Resis tan ce

Ranges

200 Ω, 2 kΩ, 200 kΩ, 20 MΩ, 2000 MΩ

Resolution

0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ, 1 MΩ

Accuracy

200 Ω to 200 kΩ ranges: ±(1.0 % rdg + 4 dgts)
20 MΩ range: ±(2.0 % rdg + 4 dgts)
2000 MΩ range: ±(5.0 % rdg + 10 dgts)

Open Circuit Voltage (typical) 0.3 VDC (3.0 VDC on 200 Ω, 2000 MΩ range)
Overload Protection

500 VDC/ACrms

Capacitance

Ranges

2 nF , 20 nF, 200 nF, 2.0 uF, 20 uF

Resolution

1 pF, 10 pF, 100 pF, 1 nF, 10 nF

Accuracy

±(4 % rdg + 10 dgts)

Overload Protection

Discharge capacitor before connecting

Fre qu ency

Ranges

2 kHz, 20 kHz, 200 kHz, 2 MHz, 20 MHz

Resolution

1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz

Accuracy

±(0.1 % rdg + 3 dgts)

Sensitivity

2.0 Vrms minimum

Minimum Pulse Width

>25 ns

Duty Cycle Limits

>30 % and <70 %

Overload Protection

500 VDC/AC rms

Diode Te st

Test Current

1.0 mA (typical)

Resolution

10 mV

Accuracy

±(1.5 % rdg + 3 dgts)

Open Circuit Voltage

3.0 VDC (typical)

Overload Protection

500 VDC/ACrms

Con tinuity

Audible Indication

Less than 100 Ω

Response Time

100 ms

Overload Protection

500 VDC/ACrms

Transis tor hFE

Range

0 to 1000

Base Current

Approximately 10 uADC (V

CE

= 3.0 VDC)

Logic Te st

Threshold

Logic Hi (2.8 V +0.8 V) / Logic Lo (0.8 V +0.5 V)

Indication

40 msec beep at logic Lo

Overload Protection

500 VDC/AC rms

General

Display

3 1/2 digit, 2000 count LCD

Polarity

Automatic, positive implied, negative polarity indication

Overrange

OL or -OL is displayed

Low Battery Indication

Battery symbol will display when battery voltage drops
below operating levels

Measurement Rate

2.5 times per second

Operating Environment

0ºC to 50ºC at <70 % relative humidity

Storage Environment

-20ºC to 60ºC at 0 to 80 % relative humidity

Accuracies

Stated accuracy at 23ºC +5ºC at <75 % relative humidity

Temperature Coefficient

0.1 x (specified accuracy) per ºC. (ºC to 18ºC, 28ºC to 50ºC)

Power

Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22

Battery Life

150 hours typical

Dimensions

165 mm (H) x 78 mm (W) x 42.5 mm (D)

Weight

Approximately 10 oz. (285 g) with battery and hanger

Manual Ranging True RMS Tool Kit

®

DMM

Model 2707B

Data Sheet

Technical data subject to change
© B&K Precision Corp. 2013
Page 1 of 2

w w w.bk prec ision.c om

The 2707B is a full-featured manual ranging true RMS DMM that combines
performance, value and functionality. The 2000 count LCD can display resistance
values up to 2 GΩ, capacitance to 20 uF, or a transistors common-emitter gain
value up to 1000. Value-packed features make this meter a must in every "Tool
Kit

®

".

Features

Magnetic hanger

One-handed operation

True RMS

Measures up to 10 A (AC & DC)

DC voltage to 1000 V

AC voltage to 750 V

Resistance to 2000 MΩ

Capacitance to 20 uF

Continuity test

Diode test

Logic test

hFE Transistor test

D C Volts

Ranges

200 mV, 2 V, 20 V, 200 V, 1000V

Resolution

0.1 mV, 1 mV, 10 mV, 100 mV, 1 V

Accuracy

±(0.8 % rdg + 1 dgts)

Input Impedance

10 MΩ

Overload Protection

1000 VDC or 750 VACrms*

A C Volts (T rue RM S) (50 Hz -500 Hz )

Ranges

200 mV, 2 V, 20 V, 200 V, 750V

Resolution

0.1 mV, 1 mV, 10 mV, 100 mV, 1 V

Accuracy

200 mV & 20 V ranges: ±(1.5 % rdg + 8 dgts)
200 V & 750 V ranges: ±(2.0 % rdg + 8 dgts)

Crest Factor

<3

Input Impedance

10 MΩ

Overload Protection

1000 VDC or 750 VACrms*

D C Cu rrent

Ranges

20 mA, 200 mA, 10 A

Resolution

10 uA, 100 uA, 10 mA

Accuracy

20 mA to 200 mA ranges: ±(1.0 % rdg + 1 dgts)

*= 600 VDC/ACrms for 15 seconds on 200 mV range

Specifications

2707B

model

Supplied Accessories: User manual, one set of test leads, one spare fuse, and 9V battery (installed)

Measures common-

emitter gain.

hFE Transist or Test

RUE RMS

T

Three-Year Warranty

Advertising