B&K Precision 308 - Datasheet User Manual

Accessories, Specifications

Advertising
background image

Accessories

60

308

305

300

Type

Analog

Analog

Analog

Digital

Output Voltage

1000VDC

500VDC

1000VDC

1000VDC

Maximum current

250µA

500µA

2mA

1.2mA

Resistance Range

1M

-2000M

0.2M

- 1000 M

1000V 0-200M

0-2000M

500V 0-100M

0-2000M

250V 0-50M

0-2000M

Center Scale

50M

20M

1M

, 2M

, 4M

Does not apply

Accuracy

Infinity: within 1% of scale length

Zero: within 1% of scale length

All points ±5% of reading

AC Voltage Test
Range

0 to 600 VDC

Live Circuit Indicator

Frequency Response

10Hz to 100kHz

Accuracy

±4% of full scale

Low resistance Test

Does not apply

0-50

0-200

Accuracy

Does not apply

±5% of reading

±(1.5% + 2 digits)

General Specifications
Power Requirements

Six “AA” cells (supplied)

Eight “AA” cells (supplied)

Battery Life

4 hours typical alkaline

12 hours continuous

10 hours continuous w/alkaline

Operating Temperature

32˚ to 122˚F (0˚ to 50˚C),

70% RH

Storage Temperature

-4˚ to 140˚F (-20˚ to 60˚C), <80% RH (with batteries removed)

Dimensions

6.66 x 4.18 x 1.42" (169 x 106 x 36mm)

7 x 8.5 x 3.5" (180 x 220 x 90mm)

Weight

15oz. (430g) w/batteries

2.6 lb (925g) with batteries

250V

500V

1000V

0-100

±(1.5%+3D) ±(1.5%+2D)

±(1.5%+2D)

100-200M

±(2%+5D)

±(1.5%+2D)

±(1.5%+2D)

200-1700M

±(3%+7D)

±(3%+4D)

±(3%+3D)

1700-2000M

±(4%+8D)

±(4%+6D)

±(4%+5D)

Models 300, 305

These insulation testers are intended primarily for periodic testing of industrial
motors, transformers, electrical wiring, and cable insulation for signs of deteri-
oration. Low readings may indicate impending failure and permit replacement
during routine maintenance rather than risking production downtime. Also
useful for safety testing of TV sets and appliances to assure
no hazardous leakage current. The voltage and resistance ratings for insulation
testing are often specified for the product to be tested.

Supplied:

Batteries, Carrying Case, Test Leads, Instruction Manual

Batteries, Integral Carrying Case w/strap, Test Lead, Instruction Manual

Specifications

models

300

305

307

308

Models 307, 308

Selectable 250V, 500V, or 1000V insulation test

Low resistance test

Extra rugged integral carrying case

Live circuit indicator warns of safety hazard

Push to test

Test insulation resistance

Measure AC voltage to 600V

Battery powered

1000V, 2000M

(Model 300)

500V, 1000M

(Model 305)

One Year Warranty

307

Advertising
This manual is related to the following products: