Battery specifications, Electric actuator & accessories, Construction and performance – Bray Electric Actuators & Accessories User Manual

Page 9

Advertising
background image

All information herein is proprietary, confidential, and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.

The technical data herein is for general information only. Product suitability should be based solely upon customer’s detailed knowledge and experience with their application.

Electric Actuator & Accessories

Specs : 9

CONSTRUCTION AND PERFORMANCE:

Housing:

• Weather Proof Enclosure (cover must not be left off when

exposed to the weather or damage will occur to the unit)

Batteries:

• Two 12V 1.4AH Sealed Lead Acid Batteries wired in

series

Battery Monitoring:

Local LED Indicator and (2) wire

voltage free normally open contact for remote monitoring

Battery Charging:

Automatic Smart Charger

Battery Conservation:

Shut-off batteries after 1 minute or

when actuator stops.

Operating Temperature:

-4ºF (-20ºC) to 122ºF (50ºC) LED

light may not function below -20 ºF

Power Protection:

Two 5 amp fuses. One is for the external

power output circuit and the other for the battery output circuit

Current Draw @ 24 VAC:

• BBU only Maximum 10mA standby (0.25 VA)
• Max. 420mA charging (10 VA)

Current Draw of Actuator with BBU:

• 600 lb-in - 1.9A (with Load)
• 2,000 lb-in - 2.7A (with Load)
• 5,000 lb-in - 4.1A (with Load)

Power Requirements:

24-27VAC or 30-38VDC (the

minimum voltage is required to provide proper battery

charging)

Power Output:

• BBU Output with 24VAC supply is 30-38 VDC

• On failure of AC supply, battery output is 24-25.5 VDC

Although charging will not work at -4°F, the batteries will still

hold their charge for an extended period of time as described

under shelf life.

Battery Specifications

Two 12 volt 1.4 ampere-hour (AH) Rechargeable Sealed Lead

Acid Battery wired in series

Features

• Valve regulated, spill proof construction allows safe

operation in any position

• Rugged impact resistant ABS case and cover (UL94-HB)

• U.L. Recognized under file number MH 20845

Specifications

• Battery Case: ABS Plastic

• Maximum Discharge Current (7 minutes):

4.2 amperes

• Shelf Life (% of nominal capacity at 68ºF (20ºC))

1 month = 97%
3 months = 91%
6 months = 83%

Operating Temperature Range

Charge: -4ºF (-20ºC) to 122ºF (50ºC)
Discharge: -40ºF (-40ºC) to 140ºF (60ºC)
The BBU should be powered up for a minimum of 12 hours to

ensure batteries are fully charged.

See “Bray Serious 70 BBU Operation and Maintenance
Manual for detailed information.

Fail Open or Close Battery Backup Unit (BBU) Specifications

Advertising