BVA Hydraulics PED0501T User Manual

Page 5

Advertising
background image

MAINTENANCE

1. Keep areas around pump unobstructed in order to provide

good air flow around the motor and pump. Try keep the

motor and pump as clean as possible.

2. Inspect hoses and connections daily. Replace damaged

components immediately with BVA Hydraulics replacement

parts only.

3. Tighten connections as needed. Use non-hardening pipe

thread compound when servicing connections.

4. Check hydraulic oil level every 40 hours of operation. Add

hydraulic oil if necessary.

5. Completely change the hydraulic oil every 300 hours of

operation. Change the oil more frequently when pump is

used in an extremely dusty environment or when the oil

has been overheated. Use only good quality hydraulic

oil. We recommend BVA hydraulic oil (F01 & F05), Mobil

DTE 15M or equivalent. To order the oil, refer to service

parts section.

Note: Use only a good quality hydraulic oil. Never use brake

fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin

etc. Use of other than recommended hydraulic oil, will void

warranty and damage the pump, hose, and application.

Adding Hydraulic Oil

1. Make sure electric motor is OFF.

2. Depressurize and disconnect hydraulic hose from

application.

3. Remove vent cap on the top plate of the reservoir.

4. Use a funnel to fill reservoir to about 2” from top of reservoir

plate.

5. Wipe up any spilled fluid and reinstall the vent cap.

5

Changing Hydraulic Oil

1. For best results, change hydraulic oil once a year.

2. Remove drain plug, tilt the pump then pour used fluid into

a sealable container.

3. Dispose the hydraulic oil in accordance with local

regulations.

4. Fill hydraulic oil, then reinstall vent cap.

Cleaning

Clean oil filter screen periodically with nonflammable solvent,

then blow dry before reassemble back to pump.

Storage

1. When not in use, depressurize and disconnect hydraulic

hoses from application.

2. Wipe clean, thoroughly.

3. Store in clean, dry environment. Avoid temperature

extremes.

4. For transportation or long term storage, shield pump with

a protective cover.

Advertising