Danger – BVA Hydraulics PS33L User Manual

Page 5

Advertising
background image

5

!

DANGER

TO AVOID ELECTROCUTION HAZARD:

• Do not operate this device in an explosive atmosphere or

in the presence of conductive liquids.

• Owner, Operator must

read, understand and

follow all printed material provided with this

device

before use.

• Connect

ONLY to properly grounded electrical

source. Connect to

GFI outlet ONLY! For use

in

dry locations.

• Avoid the use of extension cords. If used, extension cord

lengths up to 25 ft shall be SJT-14X3 or heavier. For cords

up to 50 ft, use SJT-12X3 or heavier. For extension cord

lengths up to 100 ft, use SJT-10X3 or heavier.

NEVER

use a 3 prong adapter.

OPERATION

Note: A dump valve with 2-way, 2-position is equipped on the

pump to use with Single-acting cylinders or applications.

1. Check oil level, add oil if necessary.

2. Make sure system fittings and connections are tight and

leak free.

3. Turn the flipper control valve counter-clockwise to HOLD

position.

4. Start the pump by pressing and holding the switch on

remote pendant. Oil advances the cylinder or application

when the unit is activated.

5. Always monitor the pressure, load and position.

6. Release the switch on remote pendant when desired

pressure, load or position is reached.

7. To retract the cylinder or application, turn the flipper control

valve clockwise to RELEASE position.

8. Depressurize all connections before disconnect.

MAINTENANCE

1. Keep areas around pump unobstructed in order to provide

good air flow around the motor and pump. Try keep the

motor and pump as clean as possible.

2. Inspect hoses and connections daily. Replace damaged

components immediately with BVA replacement parts

only.

3. Tighten connections as needed. Use non-hardening pipe

thread compound when servicing connections.

4. Check hydraulic oil level every 40 hours of operation. Add

hydraulic oil if necessary.

5. Completely change the hydraulic oil every 300 hours of

operation. Change the oil more frequently when pump is

used in an extremely dusty environment or when the oil

has been overheated. Use only good quality hydraulic oil.

We recommend Mobil DTE 15M or equivalent. To order

the oil, refer to service parts section.

Note: Use only a good quality hydraulic oil. Never use brake

fluid, transmission fluid, turbine oil, motor oil, alcohol, glycerin

etc. Use of other than recommended hydraulic oil, will void

warranty and damage the pump, hose, and application.

Adding Hydraulic Oil

1. Make sure electric motor is OFF.

2. Depressurize and disconnect hydraulic hose from

application.

3. Remove vent cap on the top plate of the reservoir.

4. Use a funnel to fill reservoir to about 2” from top of reservoir

plate.

5. Wipe up any spilled fluid and reinstall the vent cap.

Changing Hydraulic Oil

1. For best results, change hydraulic oil once a year.

2. Remove drain plug, tilt the pump then pour used fluid into

a sealable container.

3. Dispose the hydraulic oil in accordance with local

regulations.

4. Fill hydraulic oil, then reinstall vent cap.

Cleaning

Clean oil filter screen periodically with nonflammable solvent,

then blow dry before reassemble back to pump.

Storage

1. When not in use, depressurize and disconnect hydraulic

hoses from application.

2. Wipe clean, thoroughly.

3. Store in clean, dry environment. Avoid temperature

extremes.

4. For transportation or long term storage, shield pump with

a protective cover.

Advertising