Position 1: Pressured

oil flows to port A, port B

returns flow to reservoir

Position 3: Pressured

oil flows to port B, port A

returns flow to reservoir.

Position 2: Neutral,

ports A and B are

closed. Hold Position.

Port B

Port B

Port B

P R

P R

P R

(a) 4-way, 3-position valve for Double Acting Cylinder

Position 1 (Advance):

Pressured oil flows to

port A.

Position 3 (Retract):

Port A returns flow to

reservoir

.

Position 2 (Hold):

Neutral, port A is closed.

Hold Position.

Port A

Port A

(b) 3-way, 3-position valve for Single Acting Cylinder

(to tranfer

from 4-way valve to 3-way valve, contact BVA Hydraulic Technical

Sevice 888-332-6419)

Port A

Port B

3

1

2

P R

P R

P R

Figure 4

- Flowpath of the valve positions and operations for Model P8701M.

MAINTENANCE

1. Inspect hoses and connections daily. Replace damaged

components immediately with BVA Hydraulics

Replacement Parts only.

2. Tighten connections as needed. Use pipe thread sealing

compound when servicing connections.

3. Use only good quality hydraulic fluid. We recommend

Mobil DTE 13M or equivalent.

Never use brake fluid,

transmission fluid, turbine oil, motor oil, alcohol,

glycerin etc. Use of other than good quality hydraulic

oil will void warranty and damage the pump, hose, and

application.

Adding Hydraulic Fluid

1. Depressurize and disconnect hydraulic hose from

application.

2. With pump in its upright, horizontal position, remove vent

screw located on top of the reservoir.

3. Use a small funnel to fill reservoir to within 1/4” (6mm)

of the opening.

4. Wipe up any spilled fluid and reinstall the vent screw.

Changing Hydraulic Fluid

For best results, change fluid once a year.

1. Remove drain plug, then drain used fluid into a sealable

container.

2. Dispose of fluid in accordance with local regulations.

3. Reinstall drain plug.

4. Remove vent screw and fill reservoir with a good quality

hydraulic oil until ~1/4” (6mm) from the opening.

5. Reinstall vent screw.

Lubrication

Use a light machine oil to lubricate pivot points, hinges

etc.

Storage

1. When not in use, depressurize and disconnect hoses

from application.

2. Close vent screw by turning it clockwise hand tight.

3. Wipe clean thoroughly.

4. Pump should be stored where protected from the

elements, abrasive dust, and damage. Store in clean,

dry environment. Avoid temperature extremes.

5. Pumps must be stored upright and horizontal ONLY.

6. Shield pump with a protective cover.

Port A