Warning – BVA Hydraulics PEW0501, PEW1002, PEW1503, PEW3005 User Manual
Page 3
3
Figure 2 - Typical PE series Electric Pump Components
(PE1002 shown)
Control Valve
Lever
Electric Motor
Power Cord
Vent Cap
Control Box
Electric Motor
ON/OFF Switch
Control Valve
Oil Output
Ports
Carry Handle
Drain Plug
Reservoir
SAFETY INFORMATION
Read all the INSTRUCTIONS and WARNINGS in the manual provided within. Failure to heed these warnings may
result in personal injury as well as property damage.
WARNING
!
• Do not exceed the rated capacity of this device.
• Never attempt to lift a load weighing more than the
capacity of the cylinder.
• Burst hazard exists if hose or connection pressure
exceeds rated pressure.
• Use gauge or other load measuring instrument to
monitor load.
• Use of incorrect power source will damage the motor.
• Do not use an ungrounded (two-prong) extension cord.
• Do not install, remove or rewire the motor with power
applied. Have qualified technician to install, adjust
and service the motor.
• Do not operate this device in an extreme temperature,
explosive atmosphere or in the presence of conductive
liquids.
• Always inspect hoses and connections for damage
prior to use.
• Always tie up long hair, wear protective clothing and
eye protection when operating this equipment.
• Keep hand and feet away from cylinder and workpiece
during operation.
• Ensure the device is placed on a hard, level surfaces.
• Always ensure that the chosen application is stable
to work on and around.
• Do not subject the pump and its components to shock
loads.
• Do not subject the hose to potential hazard such as
sharp objects, extreme heat or heavy impact.
WARNING
!
• Do not connect to application which can return more
oil to the reservoir than the pump reservoir can hold.
• Do not handle pressurized hose. Escaping oil under
high pressure can penetrate the skin, causing
serious injury.
• The load must be centered on the ram, or equally
distributed on multiple rams.
• Never hold or stand directly in line with any hydraulic
connections while pressurizing.
• Do not work under a lifted load. This device is not
suitable for use as support device!
• Release all line pressure before disconnecting hoses.
• When loading a cylinder, always insure that coupler,
port, and adapter threads have not been damaged.
• Failure to heed these warnings may result in personal
injury as well as property damage.
• If oil leakage is detected, discontinue use of the pump
immediately and contact your nearest BVA Hydrau-
lics Authorized Service Center.
WARNING
!
To avoid crushing and
related injuries:
Do not work on, under or
around a lifted load.
Power Cord
Vent Cap
Reservoir
Oil Output
Ports
Carry Handle
Drain Plug
Control Valve
Lever
Electric Motor
Control Valve
Remote
Pendant
Figure 3 - Typical PEW series Electric Pump Components
(PEW1002 shown)