BVA Hydraulics P1201, P1201S, P2301, P2301M, P4301 User Manual

Page 5

Advertising
background image

OPERATION

WARNING: ALWAYS monitor pressure, load or position

using suitable equipment. Pressure may be monitored by

means of an optional manifold and gauge (contact BVA

Hydraulics). Load may be monitored by means of a load

cell and digital indicator. Correct application position can

only be determined by the operator of the equipment.

1. Remove the threaded plug, then connect the pump to

suitable application.

2. Ensure the oil level is correct and the system fittings and

connections are leak free before operating the pump.

3. Pump may be used in horizontal and vertical position

as illustrated on Figure 6.

5

Position 1: Pressurized

oil flows to port A, port B

returns flow to reservoir

Position 3: Pressurized

oil flows to port B, port A

returns flow to reservoir.

Position 2: Neutral,

ports A and B are

closed. Hold Position.

Port A Port B

Port A Port B

Port A Port B

P R

P R

P R

(a) 4-way, 3-position valve for Double Acting Cylinder

Position 1 (Advance):

Pressurized oil flows to

port A.

Position 3 (Retract):

Port A returns flow to

reservoir

.

Position 2 (Hold):

Neutral, port A is closed.

Hold Position.

Port A

Port A

Port A

(b) 3-way, 3-position valve for Single Acting Cylinder

Port A

Port B

1

2

3

P R

P R

P R

Figure 7

- Flowpath of the valve positions and operations for Model P2301M.

Figure 6 - Horizontal and Vertical Position

For models P1201, P1201S, P2301 & P4301:

A. Close release valve by turning it clockwise. Finger tight

ONLY. Using tools on release valve can damage it and

cause the pump to malfunction.

B. Pump handle until desired pressure, load or position is

reached.

C. Pressure will maintain until the release valve is opened.

D. To retract application, turn the release valve knob slowly

counterclockwise (never more than 2 full turns).

CAUTION: NEVER operate pump with release valve

closed and disconnected from application. If operated

in this condition, the hose and connections become

pressurized. This increases burst hazard. Damage may

occur to pump and its components.

For model P2301M:

Use the control valve lever to control the direction of hydraulic

oil flow, refer to Figure 7(a) below. Pump handle until desired

pressure, load or position is reached.

WARNING: Operate double-acting cylinder only when

both hoses are connected to the pump. If one coupler

is left unconnected, high pressure will build behind

the coupler which could cause personal injury and/or

equipment damage.

NOTICE: To use with 3-way setting shown in Figure 7(b)

such as single acting cylinders, please have an authorized

service center changes the valve to 3-way valve. Consult BVA

Hydraulics Technical Service 888-332-6419.

!

!

!

Advertising