BEFORE USE

Read, understand, and follow

all printed materials carefully

before attempting to assemble or operate these pumps.

NOTICE: E-Pumps are shipped dry. Add oil before use.

Electrical Connections:

Compare motor nameplate against power availability

to prevent motor burnout and dangerous electrical

overloading. The motors are wired for 110-125 volts unless

otherwise specified.

DANGER: Motor, connections and remote on/off switch

are energized components containing line voltage.

Ensure supply is grounded and GFI protected.

Hydraulic Connections:

1. Make sure to use the hydraulic oil specified by the

manufacturer. Ensure oil level in reservoir is ~

2" from top

of reservoir plate, with cylinders retracted and motor off.

2. Use of pressure gauge is strongly recommended. Attach a

pressure gauge between the pump and cylinder to monitor

pressure on cylinder.

3. Make sure coupler, hose, valve, gauge are tighten securely

to prevent accidental removal of components while in use.

Hoses

must not be kinked or twisted.

NOTICE: Always secure threaded port connections with non-

hardening pipe thread compound. Take care not to introduce

compound into port orifices.

To ensure smooth operation, bleed air from the system by fully

advancing and retracting the cylinder several times.

4. Do not exceed the rated capacity of the equipment connected

to the pump. Ensure that

all hydraulic equipment used

with this pump is rated at 10,000 psi or greater.

OPERATION

WARNING: ALWAYS monitor pressure, force and load

position. Pressure may be monitored by means of an

optional manifold and gauge. Force may be monitored

by means of a load cell and digital indicator. Correct

application position can only be determined by the

operator of the equipment.

1. Check oil level, add oil if necessary.

2. Make sure system fittings and connections are tight and

leak free.

3. Place control valve lever in the middle (Neutral/Hold)

position to prevent accidental lifting or moving of load.

4. To

start the motor: Toggle the ON/OFF switch located on

the control box to 'ON' position

OR for momentary use:

Leave control box switch in the 'OFF' position and toggle

remote ON/OFF pendant switch.

5. It is recommended to use to ON/OFF switch at the

control

box to let the pump idle for a few minutes before putting

into operation.

WARNING: This pump is for use with a single acting

cylinder ONLY! Connect one hose from either pump

oil output port to the input port of a single acting

application such as a cylinder. Block the unused output

port securely. This model can not be used with double

acting cylinders.

6. Use the control valve lever to control the direction of fluid

flow. These pumps are equipped with a 3-way 3-position

valve for use with single acting cylinder applications

ONLY.

Refer to Figure 3 below for the flow path.

7. Always monitor the pressure, load and position.

8. Do not exceed the rated capacity of the equipment

connected to the pump. To

reduce system component

stress, material fatigue, and the risk of personal injury

and property damage,

never load a hydraulic application

(cylinder, spreader, etc.) to more than 80% of its rated

capacity.

9. Shift the control valve until the desired pressure, load or

position is reached.

Note: Do not continue to operate pump

after cylinder plunger is fully extended or retracted.

10. To

turn off the motor: Toggle the ON/OFF switch on the

control box to 'OFF' position.

11. Depressurize all connections before disconnect. If you

have any questions, call BVA Technical Service @ (888)-

332-6419.

Position 1 (Advance):

Pressured oil flows to port A.

Position 3 (Retract):

Port A returns flow to

tank.

Position 2 (Hold):

Neutral, ports A is

closed. Hold Position.

Port A

Port A

Port A

P T

P T

Figure 3- Schematic flow path, valve position of 3-way, 3-position valve for Single Acting Cylinder

Port A

Port B

1

2

3

5

!

!

!

P T

Advertising