SAFETY AND GENERAL INFORMATION

Save these instructions. For your safety, read and

understand the information contained within. The owner and

operator shall have an understanding of this product and safe

operating procedures before attempting to use this product.

Make certain that the operator thoroughly understands the

inherent dangers associated with the use and misuse of the

product. If any doubt exists as to the safe and proper use of this

product as outlined in this factory authorized manual, remove

from service immediately.

Inspect before each use. Do not use if broken, bent, cracked

or otherwise damaged parts are noted. If any component of

this product has been or suspected to have been subjected

to a shock load (a load dropped suddenly, unexpectedly upon

it), discontinue use until checked out by a

BVA Hydraulics

authorized service center.

Owners and operators of this

equipment shall be aware that the use and subsequent repair

of this equipment may require special training and knowledge.

It is recommended that an annual inspection be done by

qualified personnel and that any missing or damaged parts,

decals, warning / safety labels or signs be replaced with

factory authorized replacement parts only. Any component

of this Maintenance Kit that appears to be damaged in any

way, is worn or operates abnormally shall be removed from

service immediately until such time as it can be repaired/

replaced. Labels and Instruction Manuals are available from

manufacturer.

PRODUCT DESCRIPTION

BVA Hydraulics

Maintenance Kits are designed to be used

for pushing, spreading, and pressing of vehicle body panels

as well as various component parts and assemblies. A variety

of attachments are included. J50040 is rated at 8,000 PSI;

J50100 is rated at 10,000 PSI. Rams are rated from 4 to 10

tons respectively.

WARNING: To reduce the risk of personal injury and/

or property damage, ensure that the rated working

pressure of each pressurized attachment be equal to or

greater than the rated working pressure developed by

the hydraulic pump.

WARNING: Always check connections before using.

Altering this product is strictly prohibited. Use only those

adapters and attachments provided and approved by

the manufacturer.

NOTICE: When extension tubes and/or offset attachments

are used, the rated capacity is always reduced by 50% for

each tube or offset attachment connected. See Parts Section

for identification of “offset” attachments.

BEFORE USE

1. Before using this product, read the owner’s manual

completely and familiarize yourself thoroughly with the

product, its components and recognize the hazards

associated with its use.

2. Inspect before each use. Do not use if bent, broken, leaking

or damaged components are noted.

3. Check to ensure that all parts of your kit are included (see

illustration and parts list).

2

Figure 1 - J50040 and J50100 Components

Dust Cover

Oil Filler

Screw

Handle

Release Valve

Plunger

Hose

Hose

Coupler

Ram Coupler

Cylinder

4. Carefully remove the dust caps and plugs from hose coupler

and ram coupler.

5. Connect hose coupler to ram coupler, ensure that there are

no fluid leaks.

6. Locate and open release valve. Close release valve

clockwise and pump handle until ram is fully extended,

then open release valve counter-clockwise until ram has

fully retracted.

7. With ram fully retracted and release valve open, place pump

in horizontal position. Open oil filler screw (on reservoir

body, near the back). This will release air trapped within

the reservoir. Retighten the oil filler screw.

8. If using with air actuated units, an air source of at least 7.8

CFM @ 110 PSI is required.

ADDITIONAL SAFETY INFORMATION

1. Ensure that attachments are fully engaged before applying

load.

2. Ensure that load is centrally applied to attachment or ram

saddle. Do not load off center.

3. Always monitor the force applied to workpiece by using a

load cell and indicator, or monitor pressure developed in

the ram by using an inline pressure gauge, then calculate

the applied force using the formula:

F = P x A, where F = lbs force, P = pressure in PSI, and A

= effective ram area in in

2

.

Ram Area of Model J50040 is: 0.998 in

2

Ram Area of Model J50100 is: 2.411 in

2

Refer to Load-Pressure correlation chart on page 10. If

bowing or bending of ram or any attachment occurs during

use,

"STOP", release pressure immediately and reconsider

application. Application may not be compatible with product,

a ram kit with a higher capacity may be needed.

!

!