Carlon P&C Flex - Low Res User Manual

Conduit fittings, P&c flex, Installation & fittings

Advertising
background image

Made in the U.S.A.

P&C Flex

®

Installation & Fittings

www.carlonsales.com

Part Std.

Std. Ctn.

No.

Size

Ctn. Qty.

Wt. (lbs.)

E940H

1

1

/

2

"

25

4

E940J

2"

30

5

E940K-CAR

2

1

/

2

"

4

2

E940L-CAR

3"

5

3

E940M

3

1

/

2

"

20

13

E940N-CAR

4"

5

4

Couplings

Part Std.

Std. Ctn.

No.

Size

Ctn. Qty.

Wt. (lbs.)

P258H

1

1

/

2

"

50

2

P258JT

2"

60

3

P258K

2

1

/

2

"

25

2

P258LT

3"

30

3

P258NT

4"

48

8

Plugs

1. Trenching

Trench should be graded true and free from stones or soft
spots. Backfill should also be free of stones and be firmly
tamped around the sides of the conduit, to develop maximum
supporting strength. Tamping on top of the conduit is not
recommended.

2. Backfill

In rocky soil where it is impossible to have an even trench
bottom, a selected backfill should be put in before laying the
conduit. Selected backfill (not tamped) at least 6" over the

top of the conduit is recommended. After
final backfill is placed, taming may be used
to finish the grade.

3. Duct Placement

Duct may be unreeled directly into trench or
along side trench and subsequently placed
in trench. After placing in trench, secure one
end and stretch it by hand to take up the
slack. Spot backfill to hold in position. Do
not use mechanical stretching equipment.

4. Changes in Direction

Avoid unnecessary turns, dips, or changes in direction. Keep bends as gradual
as possible to assure ease of cable pull-in after duct installation.

5. Pneumatic Rodding

All commonly used vacuum or pressure can be used to rod P&C Flex. The line
carrier (mouse, puck, rocket) should be soft, flexible material designed to fit
snugly into duct without interference.

6. Mechanical Rodding

All commonly used mechanical rodding equipment can be used to rod P&C
Flex. The tip should have a ball-type arrangement to keep rod from catching in
the convolutions on the inside of duct.

P&C Flex

®

Conduit Fittings

Part Std.

Std. Ctn.

No.

Size

Ctn. Qty.

Wt. (lbs.)

E997H-CAR

1

1

/

2

"

10

.9

E997J-CAR

2"

10

1.2

E997K-CAR

2

1

/

2

"

10

1.9

E997L-CAR

3"

10

2.1

E997M

3

1

/

2

"

40

10.2

E997N

4"

30

10.7

Bell Ends

(Schedule 40)

Part Std.

Std. Ctn.

No.

Size

Ctn. Qty.

Wt. (lbs.)

E942H

1

1

/

2

"

25

3

E942J

2"

30

6

E942K-CAR

2

1

/

2

"

4

1.4

E942L-CAR

3"

3

1.5

E942M

3

1

/

2

"

20

12

E942N-CAR

4"

7

5

Female

Adapters

Part Std.

Std. Ctn.

No.

Size

Ctn. Qty.

Wt. (lbs.)

E943H

1

1

/

2

"

25

3

E943J

2"

5

7

E943K-CAR

2

1

/

2

"

5

1.2

E943L-CAR

3"

5

2

E943M

3

1

/

2

"

30

14

E943N-CAR

4"

5

3

Terminal

Adapters

49

P&C Flex

®

Corrugated Flexible Conduit Installation

Techniques

STRETCH DUCT IN ONE DIRECTION
AWAY FROM SECURED END

SPOT BACKFILL
KEEP BENDS AS GRADUAL
AS POSSIBLE

SECURE END

Gross Automation (877) 268-3700 · www.carlonsales.com · [email protected]

Advertising