Led indicator functions tables 5 & 6, Batteryminder – BatteryMINDer 12248-AA User Manual

Page 32

Advertising
background image

Rev. C-020907

P/N VDC12248AA-MNL

BatteryMINDer

®

Model 12248-AA

Page 2

DETAILED SPECIFICATIONS - VDC Model No. 12248-AA (con’t.)

Battery sulphation check period (After absorption charge is finished): 10 minutes
Unloaded output voltage when battery is disconnected: 0.5 Vdc (max.)
Output short-circuit current when battery disconnected: 5mA dc (max.)
Battery flow back current (to the charger) when connected to 12V battery, AC Power disconnected:
0 (max.) mA dc
All LED indicators will shut off if AC power is disconnected for 5 Minutes
Full time Desulphation output pulse current control Ip-p ± Adc
Full time Desulphation output PWM* frequency 100 ±10Hz
Full time Desulphtation duty 0.%
*Pulse Width Modulated
Temperature Compensation (with ABS-248 Battery Temperature Sensor)
detailed on pages 21 -24.

GREEN

GREEN

GREEN

2A

4A

8A

2A

ON

OFF

OFF

4A

OFF

ON

OFF

8A

OFF

OFF

ON

RED

RED

RED

GEL

AGM

FLOODED

GEL

ON

OFF

OFF

AGM

OFF

ON

OFF

FLOODED

OFF

OFF

ON

LED Indicator functions

Tables 5 & 6

Advertising