QP Compressors

BelAire ELITE and QP models come equipped with low oil level switches and automatic tank
drains. The QP models also include protection against over-heating.

Page 8

Low Oil Level Switch

OIL

Target Oil Level

Oil Vent
Plug

The function of the low oil level switch
is to keep the air compressor from
starting if the oil level drops beyond
a certain point.

For compressors outfitted with the
low oil level switch, the oil should
in the top 1/3 of the oil sight glass.

When changing or adding oil, it is
important to remove the Oil Vent
Plug to allow for the oil to flow
completely into the switch.

(Please Note: If overfilled, oil will flow out
of the oil vent hole)

Thermal Protection - QP Models

If the cooling fan were to fail or
internal temperature were to reach
170°F the QP models are outfitted
with a thermal fuse.

When tripped, the fuse can be reset.
The canopy will need to be removed
to reset the thermal fuse.

Location of Fuse
(Inside Canopy
Behind Fan)

Press to
Reset

You have purchased a state of the art BelAire QP compressor. The QP comes equipped with sound
attenuating enclosure. For maintenance, the canopy and side foam pieces will need to be removed.

To remove the canopy, simply remove the 6 fasteners and lift the canopy straight up and off.