BRAND Hydraulics LEFC FLOW CONTROL User Manual

Lefc flow control installation & user guide, Specifications, Features

Advertising
background image

04/14

LEFC FLOW CONTROL

INSTALLATION & USER GUIDE

SPECIFICATIONS:

Max. 3000 psi cartridge input pressure.

Nominally Rated for 3000 psi (207 bar).

Tank Port - #4 SAE (10 psi (0.69 bar)

MAX. back pressure)

Weight 32–3/4 lbs. (14.9 kg).

25-Micron Filtration or Better.

Coil 12 VDC standard.

10.4 Ohms.
14 Watts

.

1.15 Amp max.
Rated 100% continuous duty cycle

Pulse Frequency (90 to 110 Hz)

Operating Temperature: -20 to 210F (-30 to
100C)

FEATURES:


CF port (Controlled Flow) - Flow coming from the CF port is pressure compensated and proportional to the current
received by the coil. Flow can vary from closed to wide open.

EX port (Excess Flow) - Flow coming from the EX port is also pressure compensated. Note: When zero current is
received by valve entire flow will exit valve via the EX port.

MOUNTING & ADJUSTMENT INSTRUCTIONS:


Mounting – Valve can be mounted in any orientation. Valve must be mounted on a flat surface. Special attention should
be paid to not bend or twist the casting when mounting. Doing so may cause the compensator spool to bind, causing
valve to fail.

Manual Override Adjustment – The flow rate from the valve can be manually adjusted. This feature can be used if
power to the coil is lost for any reason.

To manually adjust valve flow: First, remove the red rubber guard from adjustment screw. Next, loosen the 5/16”
jam nut. Finally, turn the override set screw clockwise with a 5/32 allen wrench to manually adjust the flow out of
the CF port

.

Cartridge Tank Port

The cartridge valve body has a tank port (#4 SAE fitting) machined into it. In order for the

internal cartridge valve to operate correctly, it must be plumbed back to tank with a MAXIMUM of 10 psi back pressure
allowed. We recommend plumbing the tank port directly back to tank avoiding any filter.

FREQUENTLY ASKED QUESTIONS:

Q: Can the CF port be blocked or plugged?
A: No. If the CF port is blocked or plugged for any reason the compensation spool will attempt to compensate for increasing
pressure, and shift thus blocking the EX port as well, and rendering valve inoperable. DO NOT BLOCK CF PORT.

Q: Can the EX port be blocked or plugged?
A: The EX port can be blocked or plugged, but doing so requires a pressure compensated or load sense pump.

Q: Can flow be sent in reverse through valve.
A: It is not recommended to send flow in reverse, as it will cause valve to become inoperable.

Q: How many amps are required to shift orifice spool to full flow?
A: 0.85 amp is required to fully shift orifice spool. 250 mA is generally the amperage needed to see flow begin from the CF
port.

Advertising