BRAND Hydraulics HIGH FLOW NON ADJUST. FLOW DIVIDER (B100-24SAE) User Manual

Specifications, Features, Mounting instructions

Advertising
background image

04/14

6.62" [168.3]

7.31" [185.7]

OUTLET

OUTLET

INLET

5

.3

8

"

[1

3

6

.5

]

BRAND HYDRAULICS

OMAHA

3.00" [76.2]

6

.0

0

"

[1

5

2

.4

]

4X Ш0.34" [Ш8.7]

B100-24SAE

HIGH FLOW NON ADJUST. FLOW DIVIDER (B100-24SAE)

INSTALLATION & USER GUIDE

SPECIFICATIONS:

Rated for 3000 psi (207 bar).

B100 is rated for 30-120 gpm (113-454 lpm).

30-Micron filtration recommended.

Weight - B100 = 26 lbs. (11.8 kg).

Standard port sizes.
-

#24SAE (1-7/8-12) all ports.

FEATURES:


Receives single stream, and divides into two streams. The two outlet flows are pressure compensated and the sum of two
flows equal inlet flow. Capable of free reverse flow. (Reverse flow is not metered.)

MOUNTING INSTRUCTIONS:


Mounting – Valve can be mounted in any orientation. Valve must be mounted on a flat surface. Special attention should
be paid to not bend or twist the casting when mounting. Doing so may cause the compensator spool to bind, causing
valve to fail. It is recommended to install washers between casting and mounting surface.

FREQUENTLY ASKED QUESTIONS:

Q: What happens if I block one outlet port?
A: If one outlet port is blocked or plugged for any reason the compensation spool will attempt to compensate for increasing
pressure, and shift thus blocking the other outlet port. This will in turn cause the valve to fail.