BRAND Hydraulics DC DIRECTIONAL CONTROL VALVE User Manual

Specifications, Mounting, adjustment & assembly instructions, Frequently asked questions

Advertising
background image

04/14

DC DIRECTIONAL CONTROL VALVE

INSTALLATION & USER GUIDE

SPECIFICATIONS:

Rated for 0-45 gpm (0-170 lpm).

Rated for 3000 psi (207 bar).

Std. port sizes (Consult factory for others).

-

3/4” NPT all ports.

-

#16 SAE (1-5/16-12) all ports.

Weighs 16 lbs. (7.3 kg).

20 – Micron filtration recommended.

MOUNTING, ADJUSTMENT & ASSEMBLY INSTRUCTIONS:


Mounting – Valve can be mounted in any orientation. Valve must be mounted on a flat surface. Special attention should
be paid to not bend or twist the casting when mounting. Doing so may cause the valve to fail.

Relief Adjustment – Relief setting is factory preset to 1500 psi, unless otherwise noted within model code. Relief valve
can be set anywhere within the range of 500 psi to 3000psi.

To adjust relief pressure: First, remove chrome hex plug above with a 7/8” combination wrench, and set aside.
You will then have access to the relief set screw (5/16” hex). Turning this screw clockwise 1 turn will increase
pressure approximately 800psi.

Handle Assembly – To install handle, place the ball end of the handle in the spool and then join handle and the retainer
using the supplied pin

.

Regardless of handle style, the handle retainer will be installed on valve from factory. Unless specified, the clevis’s
placement is defaulted so the handle points up when the valve is placed on a flat surface. To change this, prior to
handle installation, the screws holding the retainer/clevis must be removed and the clevis can then be rotated 180º
around the spool.

FREQUENTLY ASKED QUESTIONS:

Q: Can I plumb another valve downstream from this valve, using the outlet of this valve?
A: No. The outlet of this valve should be plumbed back to tank.

Q: What kits are available for this valve?
A: There is a replacement seal kit (Part #: DC-K), and replacement relief kit (Part #: TS-B) for this valve. There are also a
number of different kits available for this valve depending on the spool action, and handle option the valve is equipped with.
Please contact factory for specific kit numbers relating to different spool actions, and handle options.

Q: Can I paint the valve?
A: Painting valves is acceptable as long as the following precautions are taken:

1- All ports must be plugged
2- Spool must be masked or taped off completely.
Any paint on the spool will cause leakage when it chips off. Warranty is void if any valve is returned with paint on
the spool.

GENERAL INFORMATION:


Pipe Thread Sealant - Warranty is void when Teflon tape is used to seal pipe threads. This is because Teflon tape is a
friction reducing agent which allows customers to over-torque fittings. We recommend using a sealant that does not include
friction reducing agents i.e. Lead Plate.

Spool Information - All DC’s are built with Iosso plated spools to improve wear and corrosion resistance. For highly
corrosive environments, i.e. marine applications, we recommend using a stainless steel spool. To order a valve with a
stainless steel spool simply add “SS” to the end of the model code.

Advertising