BRAND Hydraulics DS DIRECTIONAL CONTROL VALVES User Manual

Specifications, Mounting, & assembly instructions, Frequently asked questions

Advertising
background image

05/14

DS DIRECTIONAL CONTROL VALVES

INSTALLATION & USER GUIDE

SPECIFICATIONS:

Coils: - 12 VDC, 3.5 ohms, 40 watts, & 3.5 amps
- 24 VDC, 14 ohms, 40 watts, and 1.75 amps
- 120 VAC, 300 ohms, 40 watts, and 0.40 amps

Port Sizes: - #8 SAE (3/4-16) all ports
- #10 SAE (7/8-14) all ports
- #12 SAE (1-1/16-12) all ports
- #4 SAE (7/16-20) drain port

Weight: 10.0 lbs (4.55 kg).

10 Micron Filtration Recommended.

Flow and pressure ratings for Pilot, Lever and
Knob actuated valves
#8 SAE – 10gpm (38 lpm) & 4500 psi (310 bar)
#10 SAE –18gpm (68 lpm) & 4500 psi (310 bar)
#12 SAE –30gpm (114lpm) & 4500 psi (310 bar)






MOUNTING, & ASSEMBLY INSTRUCTIONS:


Mounting – Valve can be mounted in any orientation. Valve must be mounted on a flat surface. Special attention should
be paid to not bend or twist the casting when mounting. Doing so may cause the valve to fail.

Handle Assembly – If the enclosed lever handle is desired, the handle actuator will already be installed on the valve.
When you receive the valve, simply screw the supplied lever handle into the threaded handle actuator.

FREQUENTLY ASKED QUESTIONS:

Q: Can I paint the valve?
A: Painting valves is acceptable as long as the following precautions are taken:

1- All ports must be plugged
2- Spool must be masked or taped off completely.
Any paint on the spool will cause leakage when it chips off. Warranty is void if any valve is returned with paint on
the spool


Q: When do I need an external drain?
A: The external drain is only used on Electrically Actuated “DS” valves where operating
pressures are greater than 3600 psi (248 bar) but does not exceed 4500 psi (310 bar). The internal drain plug can be swapped
out with the external drain plug (opposite the coil) if the spool seems to “stick” at higher pressures. Note: pilot, knob, and
lever actuated valves are rated to 4500 psi (310 bar).

Q: What pilot pressure is required for the pilot operated version of the valve?
A: Valve requires 150 psi pilot pressure.

Q: When are “unused open-port” spools (types F&G) beneficial?
A: In selector spools F and G, the unused ports are open to prevent line cavitation during motor freewheel.

Q: When are closed cross-over spools used as opposed to open cross-over?

A:

Closed cross-over transient position spools are recommended for switching flow between cylinders to help prevent

cylinders from shifting while in the transient position.


Q: What kits are available for this valve?
A: There is a replacement seal kit for each variation of valve (Electric = P/N#: DS-EK, Knob& Lever=P/N#: DS-K, Manual
Lever=P/N#: DS-HL, Pilot=P/N# DS-PK). There are also a number of different kits available for this valve depending on the
spool action, and handle option the valve is equipped with. Please contact factory for specific kit numbers relating to different
spool actions, and handle options.