background image

B

Certificate #02.002.1

ISO 9001:2000 WITH DESIGN

INSTALLATION SHEET FOR

POC76 STYLE PILOT OPERATED CHECK VALVE

KEEP WITH PRODUCT UNTIL INSTALLED

ADDITIONAL SHEETS MAY BE PRINTED OUT FROM OUR WEBSITE

WWW.BRAND-HYD.COM

UNDER PRODUCT CATALOG SECTION


Can I paint my valve? – Painting valves is okay as long as the all ports are properly plugged.

Pipe thread sealant – Warranty is void when Teflon tape is used to seal pipe threads. This is because Teflon tape is a friction
reducing agent which allows customers to over-torque fittings. We recommend using a sealant that does not include friction
reducing agents i.e. Lead Plate.

B

R

A

N

D

HYDRAULICS

3/8" NPT

PILOT PORT

3/4" NPT

PUMP PORT

3/4" NPT

CYLINDER PORT

S.N.

BRAND HYDRAULICS

4.56" [115.8]

3.88" [98.4]

1.75" [44.4]

4.56" [115.8]

1.62" [41.3]

.87" [22.2]

1.75" [44.4]

2X Ш17

64 [Ш6.7]

Figure 1: Dimensional Data for Pilot Operated Check valve in inches & [millimeters].

Revision 12-06

Advertising