6 specific ations – Camco Q-Power User Manual

Page 24

Advertising
background image

6 SPECIFIC

ATIONS

USER MANUAL
Q - P O W E R S E R I E S

P. 23

Q - P O W E R

S E R I E S

Q-POWER 4

Q-POWER 6

Q-POWER 10

THD+N (typical)

20 Hz - 0 kHz, 8 Ω,

 dB below rated power

< 0,02 %

< 0,03 %

< 0,05 %

Damping Factor

8 Ω,  kHz and below

>350

> 350

> 600

Maximum output voltage

99 Vp / 98 Vpp

25 Vp / 250 Vpp

45 Vp / 290 Vpp

Input Impedance

5 kΩ balanced

Voltage Gain

selectable: 26 dB, 32 dB, or ,4 V input sensitivity

Protection Circuits

inrush-current limitation, mains voltage monitoring, temperature monitoring of transformers and heatsinks,

output DC protection, SOA protection, output over current protection,

intelligent mains fuse protection,

Limiter

two individually selectable clip limiters for channels A + B and C + D

Fan

two temperature dependent speed-controlled axial fans

Indicators

LEDs for on, signal/protect, output current and clip

User Interface

four individually adjustable volume control knobs for channel A - D

Input Connectors

3-pin XLR connector per channel

3-pin Euroblock connector per channel

Output Connectors

two four-pole SPEAKON-connectors and barrier-strip-connector terminals for channel A - D

Dimensions (WxHxD)

483 x 88, x 42 mm (9”, 2U)

Net Weight

0,6 kg

0,6 kg

,5 kg

Shipping Dimensions (WxHxD)

65 x 35 x 540 mm (0,045 m

3

)

Shipping Weight

2,6 kg

2,6 kg

3,5 kg

We reserve the right to make technical alterations without prior notice.

Advertising