I-View Ethernet/PoE over Coax Extender built-in Hub User Manual

Page 2

Advertising
background image

¾

The quality of coaxial cable will reduce or increase the transmission distance. The EOC-100Kit is tested for use
with RG-59U 75 Ohm copper based 20AWG coaxial cable.

¾

That is free from damage as in cuts, breaks, or cracks to the outer covering and insulated shielding which may
compromise the signal conductivity of the cable.

¾

For safety, DO NOT put EOC signals in the same conduit as high-voltage wiring.

For more specific information regarding wire types, gauges, and proper installation techniques, please call Tech
Support at 886-3-5103001 or email to

[email protected]

—

Installation Steps

:

1. Connect the unit's RJ45 Ethernet jack to the IP camera using a standard Cat5 or Cat6 patch cable and unit's BNC

socket to a 75 ohm coax cable with BNC connector.

2. Plug the DC 12V power adapter to the EOC-100V Ethernet over Coax extender.
3. Connect the unit's (Which on the HUB site) BNC socket to a 75 ohm coax cable with BNC connector, then plug

the a standard Cat5 or Cat6 patch cable to the unit’s RJ45 Ethernet jack to the Switching HUB.

4. In order to get better transmission distance, the Ethernet patch cable should be a standard Cat5 or Cat6 cable and

less than 2 meters.

—

Troubleshooting:

The following table describes some of the symptoms, probable causes and possible solutions

Problem Possible

Cause


Hub LED indicator is
OK, but no video

9

Check IP camera and unit device connections.

9

Check coax cable condition and BNC connectors is 75 Ohm.

9

Check cable that cable distances do not exceed EOC-110V operating distance.

9

Check the built in jumper cable of IP camera used non- standard Cat. 5 cables.

9

Check that the camera is powered.


Network lost

9

Check network switch termination(s) & link status.

9

Check network routing table(s).

9

Confer with site Network Administrator.

—

Specification:

Phone: 886-3-510-3001 Fax: 886-3-510-3002

Mail: [email protected]

Item \Model

EOC-100V

EOC-110V

Ethernet

Connector: RJ-45

Speed: 10/100Base-T full-duplex


Coaxial

Connector: BNC 75 Ohm

Cable: Any 75 Ohm coax cable

Distance: 300 meters (Typ.)@ full rate via RG59U coax cable

Bandwidth: 100M bits/Second

Power Consumption

DC 12V / 50mA

None

Dimension /Weight

100 x 55 x 34 mm / 140g

55 x 25 x 25 mm / 60g

Environment

Operation: 0℃to 50℃; 20%

~

85% non-condensing

Advertising