Installation Steps:

1. Connect the EOC-110V unit's RJ45 Ethernet jack to the IP camera using a standard Cat5 or Cat6 patch cable and

EOC-110V unit's BNC socket to a 75 ohm coax cable with BNC connector.

2. Connect the EOC-110V unit's (Which on the HUB site) BNC socket to a 75 ohm coax cable with BNC connector,

then plug the a standard Cat5 or Cat6 patch cable to EOC-110V unit’s RJ45 Ethernet jack to the Switching HUB.

3. In order to get better transmission distance, the Ethernet patch cable should be a standard Cat5 or Cat6 cable and

less than 2 meters.

—

Troubleshooting:

The following table describes some of the symptoms, probable causes and possible solutions

Problem Possible

Cause

Hub LED

indicator is OK,

but no video

9

Check IP camera and EOC-110V device connections.

9

Check coax cable condition and BNC connectors is 75 Ohm.

9

Check cable that cable distances do not exceed EOC-110V operating distance.

9

Check the built in jumper cable of IP camera used non- standard Cat. 5 cables.

Network lost

9

Check network switch termination(s) & link status.

9

Check network routing table(s).

9

Confer with site Network Administrator.

—

Specification:

Phone: 886-3-510-3001 Fax: 886-3-510-3002

Email: [email protected]

Item \Model

EOC-110V

Ethernet

Connector: RJ-45

Speed: 10/100Base-T full-duplex

Coaxial

Connector: BNC 75 Ohm

Cable: Any 75 Ohm coax cable

Distance: 200 meters (Typ.)@ full rate via RG59U coax cable

Bandwidth: 100M bits/Second

Size/Weight

55 x 25 x 25 mm / 60g

Environment

Operation: -20℃to 70℃; 20%

~

85% non-condensing