Specifications, Motec – MoTeC AFM1 User Manual

Page 5

Advertising
background image

MoTeC

Specifications

1

Specifications

Meter

Operating Voltage Range

7 to 16 V DC

Operating Current

0.3 A Max. (Excluding Sensor)

Reverse Voltage

- 24 V DC Max.

Transient Protection

10 Joules (100A / 10ms) (Clamping Voltage
24V)

Operating Temperature

0 to 60 deg C

Operating Humidity

0 to 80 % Non Condensing

Measurement Range

0.75 to 1.60 Lambda

Measurement Accuracy

± 1.5% 0.75 to 1.05 Lambda
± 2.5% 1.06 to 1.25 Lambda
± 5.0% 1.26 to 1.60 Lambda

Display Update Rate

3.5 Times per second

Response Time

< 150 msec (To 63 % of Final Reading)

Weight 575

g

Dimensions

142 x 48 x 96 mm (WxHxD)

Meter Analog Output

Output Type

Isolated (Floating)

Output Isolation

400 V DC Max.

Output Voltage Range

0 to 5 V DC Max. ( Dependant on Range
Selection )

Output Current

1 mA Max.

Response Time

100 ms 0.75 to 0.95 Lambda
150 ms 0.96 to 1.05 Lambda
50 ms 1.06 to 1.60 Lambda

(To 63 % of Final Reading)

Advertising