Installation/ Assembly

The heater is to be mounted in

the vertical position.

The C distance over the heater

must be observed in order to per-

form maintenance and to exchange

the magnesium anode without tak-

ing the heater off the wall.

After the appliance has been fixed

on the wall, it has to be connected

to the water mains. After filling the

appliance entirely with water and

venting (see start-up section),

connect the heater to the electric

mains. Warranty is void if the

installation is not carried out in

accordance with the instructions.

In order to situate the appliance in

a correct place, one should take

into account that an emergency

leak from the tank will not cause

flooding of the room.

Hydraulic connection

The heater is a pressure appliance and it is adjusted mains which pressure should

not exceed 0.6MPa. If the pressure is higher than 0.6MPa, a pressure reducing valve

is to be installed before the safety valve.

A small leak from the safety valve through the outlet pipe may occur. It is a normal

operating state of the appliance. The outlet of the pipe has to remain opened. Do not

clog it, as a clogged outlet may cause a break down of the heater.

The safety valve and the outlet pipe must not be exposed to frost.

Please follow the connection instructions below.

To the inlet fitting of cold water install:

-

T – connection,

-

safety valve, making sure that the direction of the water flow is accordant with

the arrow on the casing of the safety valve,

-

drain valve according to the schematic diagram.

A draining valve allows for emptying the tank.

There must never be a cut-off valve

between the safety valve and the tank.