Fitting into wall cupboard – Neff D4982X0 User Manual

Page 32

Advertising
background image

32

Fitting into wall cupboard

Note: The extractor hood housing can be
clad inside the wall cupboard (e.g. with
chipboard).

If so, observe the following:
❑ The intermediate base must not be

placed on the extractor hood housing.

❑ Never attach cladding to the housing.
❑ Provide access for customer service.
❑ If the extractor hood is to be installed

further back in the cupboard, the stops
for the filter drawer can be moved
forwards.

❑ To do this, undo the screws, move the

stops and retighten the screws.

Re-adjusting the limit switch:

1. Check whether the extractor hood

switches off when the filter drawer is
inserted.

2. If the extractor hood does not switch off,

re-adjust the limit switch.

3. Unscrew the screw in small steps –

max. 2 revolutions.

2. Align handle

moulding
and screw
to the
appliance.

Do not

pinch the ribbon
cable.

Moving the operating unit:

See Operating instructions.

Attaching the handle moulding:

A handle moulding must be attached to
the filter drawer.
This handle moulding may be a wooden
strip which matches the kitchen units or a
handle moulding available as an optional
accessory (see optional accessories on the
back page).
1. Using the enclosed template

O

III

, mark

the attachment points on the wooden
strip and make holes with a bradawl.
When you drill:
2 mm dia – max. 10 mm in depth.

Advertising