ASB Heating Elements Ltd. Cartridge Heaters User Manual

Cartridge heaters

Advertising
background image

Cartridge Heaters

I 1

Crimped-On Leads, Figure 253

A high temperature double crimp connects the MGT
(450°C) leads to solid nickel pins. This construction
is recommended for applications with elevated
temperatures.

Due to the rigid nickel pins, this

construction is not recommended in applications
where movement or flexing is encountered, or if sharp
bends are required adjacent to the heater exit

Swaged in Leads, Figure 254

High temperature MGT (450°C) wire is internally
connected and swaged in place. This construction is
recommended for applications in which the leads must
be bent at the exit point from the heater and where
mild flexing may be found.

For applications with

continuous or more severe movement, we would
recommend metal braid or armor cable.

Stainless Steel Braid,

Figure 255

High temperature MGT (450°C) wire is internally
connected and swaged in place along with stainless
steel braid. This construction offers protection against
abrasion and sharp edges.

This is a very strong

construction which offers full length flexibility. This
construction is recommended in applications with
flexing and where the leads must pass through metal
openings or routed along metal components.

Stainless Steel Armoured Cable (Hose), Figure 256

High temperature MGT (450°C) wire is internally
connected and swaged in place along with stainless
steel hose.

This construction is recommended for

applications in which the leads are subjected to
abrasion or run the risk of being pinched. This is the
strongest lead protection available and works well in
moving or flexing applications.

Length

Lead Le

ngth

Diameter

Length

Diameter

Lead Le

ngth

Length

Diameter

Lead Le

ngth

Length

Diameter

Lead Le

ngth

Armour

Length

Figure 253

Figure 254

Figure 255

Figure 256

Advertising