A2-149 & A2-155

Regulators

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

Table 1 – Voltage Select Switch Position

4 Voltage Setpoints (Fig. 1)

Position 1

14.0 V

Position 2

14.4 V

Position 3

14.8 V

Position 4

15.5 V

Battery Type

Maintenance (D Category)

Maintenance-Free (Group 31)
Maintenance-Free (Group 31)

Battery Isolator setpoint

Note: On Group 31 batteries, if boiling or excessive gassing occurs with high voltage

setpoint (position 3), change to medium voltage setpoint (position 2).

Figure 1 – 4 Voltage Setpoints

1. Before installing, turn regulator over and select

appropriate voltage setpoint for battery type
(See Table 1 and Fig. 1).

2. Install new regulator as described below:

a. Mount new regulator on alternator in the

same position as the previous regulator.

b. Use screws and washers (if supplied).

Torque regulator mounting screws to

8.5 Nm/75 lb. in.

3. Plug the alternator-to-regulator harness into the

regulator.

4. A2-155 regulator connections:

• Connect IGN terminal to ignition source

through existing switch. Torque M5 terminal

nut on regulator to 4.5 Nm/40 lb. in.

• Connect P terminal to tachometer or relay.

P terminal taps AC voltage, typically half

the charge voltage. Torque M6 terminal nut

on regulator to 4.5 Nm/40 lb. in.

Installation Instructions

1

2 3

4

5. A2-149 regulator connections:

• D+ terminal provides 14 VDC voltage output

to multiplex controller. When connecting D+

terminal to controller through a relay, the

relay coil must be diode protected and rated

for proper voltage. Torque M5 terminal

nut on regulator to 4.5 Nm/40 lb. in.

• Connect R terminal to tachometer or relay.

R terminal taps AC voltage, typically half the

charge voltage. Torque M6 terminal nut

on regulator to 4.5 Nm/40 lb. in.