C.E. Niehoff & Co. 200 & 300: Regulator Upgrade Installation User Manual

Installation instructions

Advertising
background image

II0002C

Page 1 of 2

Series 200 & 300 Alternators

Installation Instructions

Voltage Regulator Upgrade

Field Lead

(white wire with ring terminal)

Figure 2 - Series 300 Wiring

“B-” Lead

(heavy black wire)

Field lead white wire with fl ag

terminal must be attached to heat

sink stand-off. There is no terminal on new board for
fi eld lead with fl ag terminal.

NOTICE

This symbol is used to indicate special instructions

on installation, operation or maintenance that are

important but not related to personal injury hazards.

NOTICE

Voltage Select Switch Position

A2-431 Reg. A2-432 Reg. A2-433 Reg.

Position 1—13.8 V

Position 1—27.6 V

Position 1—27.6 V

Position 2—14.2 V

Position 2—28.0 V

Position 2—28.5 V

Position 3—14.6 V

Position 3—28.5 V

Position 3—37.2 V

Position 4—14.6 V

Position 4—29.0 V

Position 4—38.3 V

300 Series – A1-300, A1-301, A1-302, A1-303, A1-305 ,
A1-306, A1-307

N1101, N1102, N1103, N1108, N1111, N1112, N1114 , N1115,
N1117, N1118, N1119, N1120, N1121, N1122, N3017, N3018,

N3037, N3038

1. No modification to cover assembly is needed.

2. New voltage regulator circuit board fits in place of old

one as shown in Figure 1.

3. Wire as shown in Figure 2.

A1-305 and N1114 may have an additional brown lead

(see Figure 1) not required for new regulator. Trim lead
and tape exposed end to insulate from contact with other
components.

Figure 1 - Series 300 Circuit Board

Brown Lead not needed

for new regulator