C.E. Niehoff & Co. A2-334/A2-335 Regulator Installation User Manual

Installation instructions

Advertising
background image

II179A

Page 1 of 1

A2-334 & A2-335

Regulators

Installation Instructions

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

Table 1 – Voltage Select Switch Position

4 Voltage Setpoints (Fig. 1)

Position 1

14.0 V

Position 2

14.4 V

Position 3

14.8 V

Position 4

15.5 V

Battery Type

Maintenance (D Category)

Maintenance-Free (Group 31)

Maintenance-Free (Group 31)

Battery Isolator setpoint

Note: On Group 31 batteries, if boiling or excessive gassing occurs with high voltage
setpoint (position 3), change to medium voltage setpoint (position 2).

Figure 1 – 4 Voltage Setpoints

1. Before installing, turn regulator over and select

appropriate voltage setpoint for battery type
(See Table 1 and Fig. 1).

2. Install new regulator as described below:
• Mount A2-334 regulator on alternator in the

same position as the previous regulator. Use
screws and washers (if supplied). Torque
regulator mounting screws to 8.5 Nm/75 lb. in.

• Mount A2-335 regulator in remote location

specified by customer.

1

2 3

4

3. Plug the alternator-to-regulator harness into the

regulator.

4. Regulator connections:
• Connect IGN terminal to ignition source

through existing switch. Torque M5 terminal
nut on regulator to 4.5 Nm/40 lb. in.

• If required, connect P terminal to tachometer

or relay. P terminal taps AC voltage, typically
half the charge voltage. Torque M6 terminal
nut on regulator to 4.5 Nm/40 lb. in.

Advertising