C.E. Niehoff & Co. A8-219 Low Frequency EMC Filter Assembly Installation User Manual

A8-219 low frequency emc filter assembly, Notice

Advertising
background image

Figure 2 – Top View of Alternator B+ Terminal or Component Power Terminal Stacking Order with EMC Filter Lead

B+ bolt

Flat washer

Red lead from

EMC Filter

Belleville washer (cup down)

B+ cable terminal or power supply terminal

Figure 1 – Installing A8-219 EMC Filter

GR

OUNDED SURF

AC

E

To B+ terminal on alternator or
power supply terminal on component
(see Figure 2 for stacking order)

A8-219

Low Frequency EMC

Filter Assembly

Installation Instructions

Page 1 of 1

II164B

To install filter assembly:

1. Disconnect battery wiring:

a. Disconnect vehicle battery master switch

and vehicle battery ground cable(s).

b. Remove cable from alternator B+ terminal

or affected component.

2. Set unit in mounting location on vehicle surface

already grounded in a location close to alternator
or affected component. Torque hardware to
8.5 Nm/75 lb. in.

Electromagnetic compatibility (EMC)/electromag-
netic interference (EMI) low and high frequencies
can interfere with the operation of electrical/
electronic systems, especially communication
equipment.
If diagnostic tests performed at system and
component level do not identify the source,
installing an EMC filter may help to reduce or
eliminate EMC condition.

If you have questions about your alternator or any of these instructions, or if you need to locate a Factory Authorized Service Dealer, please contact us at:

C. E. Niehoff & Co.• 2021 Lee Street • Evanston, IL 60202 USA

TEL: 800.643.4633 USA and Canada • TEL: 847.866.6030 outside USA and Canada • FAX: 847.492.1242

E-mail us at [email protected]

NOTICE

EMC filter can be installed at

power supply of the affected

component or at the B+ terminal

on the alternator.

3. Connect red lead provided with kit.

NOTICE

The length of the cable

supplied with the filter has

been designed to reduce most

EMC

conditions.

In severe EMC conditions,

shortening the cable may

optimize the filtering.

a. Larger terminal end to alternator B+ terminal

or component power terminal as shown in

stacking order. Torque terminal nut to torque

value specified by alternator model or compo-

nent

manufacturer.

b. Smaller terminal end to terminal on filter.

Torque to 4.5 Nm/40 lb. in.

4. Reconnect vehicle battery master switch and

vehicle battery ground(s).