C.E. Niehoff & Co. C706:A9-098 Field Coil Connector Replacement User Manual

Replacement instructions

Advertising
background image

II167B

Page 1 of 2

A9-098 Field Coil Connector Assembly

for C706 Alternators

Replacement Instructions

1. Cut field coil leads at connector terminal on both

ends of connector and strip 1/4 inch of insulation.
See Figure 1.

Figure 2 — A9-098 Field Coil Connector Assembly

Figure 3 — Splicing to Field Coil Wires

Figure 4 — Field Coil Connector Assembly

Figure 1 — Clipping Off Old Connector

2. Connect new field coil connector assembly (see

Figure 2) via splices to existing field coil wires,
then crimp them securely (see Figure 3):
• red to red
• brown to brown
• white to white
• black to black

3. Use heat gun to seal the four splices.
4. Make sure male connector is securely connected

to the female connector inside the control unit.
See Figure 4.

This kit contains a larger sized connector assembly than what it may be replacing.

Be sure to replace both sides of connector if this is the case.

Continue to page 2

CAUTION

This symbol used in these instruc-

tions indicates presence of

hazard(s) that will or can cause

minor personal injury or property

damage if ignored.

Red wire

Brown wire

Black wire

White wire

Advertising