C.E. Niehoff & Co. N7434 DE Housing Termination (Old & New) Instructions User Manual

C. e. niehoff & co, Installation instructions

Advertising
background image

II0056A

Page 1 of 1

N1225-1 Alternator/

N7434 DE Housing

Installation Instructions

C. E. Niehoff & Co.

BRUSHLESS ALTERNATORS

If your drive end housing has B+ and B–
studs and nuts, torque as follows in
Figures 1a and 1b:

Terminal on

Vehicle “B+” lead

Lock Washer

Washer

.3750-16 UNC-2B;

torque to

15 Nm / 11 lb.ft.

Figure 2a – Positive Terminal Connections

+28 V B+ Bolt

on alternator

Washer

Lock Washer

.3125-18 UNC-2A;

torque to 9 Nm / 80 lb.in.

Ground Bolt

on alternator

Terminal on

vehicle ground lead

Figure 2b – Ground Terminal Connections

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

If your drive end housing has molded B+
terminal/bolt and B– terminal/bolt, torque
as follows in Figures 2a and 2b:

Terminal on

Vehicle “B+” lead

Washer

Lockwasher

Nut, 3/8-16;

torque to

20.33 Nm / 15 lb.ft.

Figure 1a – Positive Terminal Connections

+28 V Positive Terminal

on alternator

Washer

Lockwasher

Nut, 5/16-18 UNC-2A;

torque to 13.55 Nm / 10 lb. ft.

Ground Terminal

on alternator

Terminal on

vehicle ground lead

Figure 1b – Ground Terminal Connections

Advertising