C.E. Niehoff & Co. N9191 Stud Replacement Instructions User Manual

N9191 stud, Replacement instructions

Advertising
background image

II0153A

Page 1 of 1

N9191 Stud

Replacement Instructions

This symbol is used to indicate the presence of hazards that can cause minor personal injury or

equipment damage.

This symbol is used to indicate the presence of hazards that will cause severe personal injury, death or

equipment damage.

DANGER

This symbol is used to indicate the presence of hazards that can cause severe personal injury, death or

equipment damage.

WARNING

CAUTION

Disconnect alternator, batteries, and

any other auxillary equipment before

removing cables. Failure to do so can

result in severe personal injury.

WARNING

Figure 1 - Removing Stud

CAUTION

C. E. Niehoff & Co. • 2021 Lee Street • Evanston, IL 60202 Tech Services Hotline 800-643-4633

1. Remove hardware and cables from battery studs on

isolator.

2. Using double nuts, remove stud from terminal.

See Figure 1.

3. Apply Loctite

®

222 to lower threads of new stud.

Using double nuts, install new stud until it extends
no more than an inch out of the terminal. See Figure 2.

Critical dimension: To properly

engage terminal, stud threads

must not extend more than

.94" to 1.06" from top of terminal.

4. Remove double nuts. Install hardware in stacking

order shown in Figure 3.

Failure to follow stacking order

will result in substantial

equipment damage.

M12x1.75 Stud (3 places)

Lock washer (3 places)

Flat washer (3 places)

Nut (3 places)–

torque to 30 Nm/22 lb. ft.

27mm/1.06 in. dia.

brass boss

Customer cables

to be located

under flat washer

Do not exceed recommended

torque. Component damage

will result.

DANGER

Figure 3 - Stacking Order

CAUTION

CAUTION

Figure 2 - Installing Stud

0.94" to 1.06"

(see step 3)

See step 2

Advertising